- 75
- 186 995
Fancys Regenerative Farm
Registrace 4. 07. 2016
We've Got Milk!!
In this video you will meet a couple new members on the farm and how to milk a cow, simple and easy.
zhlédnutí: 169
Video
Offgrid Tankless Propane Hot Water Heater!
zhlédnutí 9KPřed rokem
We explain how our hot water heater works well for our off grid setup.
Best Off Grid Propane Heater!
zhlédnutí 118KPřed rokem
Best heating solution for your off grid homestead or shop!
Another Early Morning for More Excitement "SURPRISE ENDING!!"
zhlédnutí 311Před rokem
Another member added to the Fancy Farm over at the Townstead! This one is a handsome one for Gloria.😉
Visit on the Townstead!
zhlédnutí 157Před rokem
A little tour of the farm at the Townstead and Exciting News!!!😃
Fireside Dreaming
zhlédnutí 337Před rokem
We spill our guts about our present, future, hopes & dreams.🙂
Fancy Farm is back!
zhlédnutí 324Před 2 lety
Update on the Fancy Farm! Loss... new additions, and more!😃
How to unload a 15k haybale with no tractor! ...Fancy farm style
zhlédnutí 139Před 2 lety
How to unload a 15k haybale with no tractor! ...Fancy farm style
Painting Experiment!😃
zhlédnutí 70Před 2 lety
Attempting a new method to painting my walls to get a marble effect. Find out if I love it or hate it!😬😄
It s the simple pleasures of life ....
zhlédnutí 518Před 2 lety
It s the simple pleasures of life ....
Incredible White Chicken Chili w/Cornbread!
zhlédnutí 64Před 2 lety
Incredible White Chicken Chili w/Cornbread!
Last minute preparation! The Bull arrives!
zhlédnutí 105Před 2 lety
Last minute preparation! The Bull arrives!
I like how you always carry a gun just in case the kids get out of hand. Smart.
Does it have a glass to protect flame from blowing out?
Anymore videos coming?
Love this video!
That is not a radiant heater that is a blue flame heater, I have a blue flame heater in my house and a radiant heater both are the same brand and rated at 30,000 BTU, the Blue flame heater does not put out as much heat and it uses more propane, I will never buy another blue flame heater again, You want a radiant heater also called infrared with ceramic plaques, they heat better and are more efficient. If you will notice when the big box stores sell out of heaters in the winter the blue flame are the only ones left on the shelf because they do not work as good.
My homeowners is trying to cancel me over my woodstove which we only use when it gets super cold so im going to replace it with one of these. I found we burn so much wood when its cold it is no cheaper as I have to buy wood.
How did the washer hold up outside?
retour au début du ,20 eme siècle, c'est vraiment n'importe quoi...
thank you for the product links so thoughtful
No ventilation, no chimney, no nothing. Just a natural convection IN YOUR OWN HOUSE. Where is the evacuation of the conbustion gases? Dude, all those toxic gases will kill you one day. Do something about it!
Hello, do you have any issues with moisture building up in the attic or walls with this heater? We ran one and condensation was building up in the attic on the ceiling as we have a Metal Roof, just curious if you need to run a dehumidifier with these units?
Excellent video. Do you think this would run off of a 5lb tank or might there be pressure issues?
Raw milk is very health. I really enjoy the thick rich cream that forms on the top after it sets for a while.
You make a great video. You explained it all very clearly. Looks like a wise choice in heating products.
Just a few acres got Dexter's
are these kiko goats?
Please talk about how much it cost to fill that tank and how much it cost to heat your home
Hey! This house looks pretty familiar!! Can’t wait till you guys are back! ❤
Good off grid option…..especially a smaller version for our cabin bathroom.
how much is that 100lbs tank cost to fill? Lasting only 7 days is not great is it.
100lb tank is 23gal. 23gal. X $2.50/gal. = $57.50 per week to heat the house. Not too bad but why not just get a 2500gal. tank so you don’t need to mess with switching and filling so much? You must live WAY out there so delivery not an option 😂
No, it’s not the best. Inferred is the best
I install heaters an deliver propane.. running the heater with just the pilot would not over heat the thermocouple.. i have a hearter that i have ran for 4 years straight summer an winter.. usually its dust that makes them shut off like that..
A thermostat controlled unit would be more better.
I absolutely love yalls home! I just found yall cause i was looking for info on the Mr Heater and was thrilled to see yall are on a similar journey that we are! We are living in a shed to house that isn't complete ❤❤❤❤❤❤❤
It would be good for power failures in the winter. ❄️ I natural gas furnace but it is forced air.
What is the sq. footage of the house in this video? Just wanting to know the area it heats for 6-7 days.
900 square feet with 14' vaulted celing
The fan kit is not for moving the heated air, it's for keeping the heater cool so it lasts longer.
What do set regulator from 0-30 psi?
Its hard to believe that people are allowed to use a ventless gas heater that is ventless inside their home . In Canada all gas heaters need to be direct vent so that the air feed to the fire comes from the outside and the exhaust fumes are vented to the outside . That is the only logical and safe way of using one of these . I get your reasoning that it is a back up only and nobody will be in the house but the unit will work more efficiently if it has good fresh air to feed the fire instead of using exhaust depleted oxygen . Oxygen will be sucked in through any window or door leak and after a while it will deplete the oxygen inside the house to an unsafe level and also the fire will not burn well using air that is depleted of oxygen . Using a direct vent gas fireplace you will not get the condensation issue from the exhaust ...Plus you will not have people inside a house full of exhaust poison gas !
These heaters burn so effecient there is no exhaust fumes ive heated with them for years with no vent.
@@chadanderson2798Combustion consumes oxygen and produces carbon dioxide. Carbon dioxide is what you need to exhaust. Otherwise you end up with a house full of carbon dioxide and depleted oxygen, which can kill humans.
It’s -38 here right now, I topped off a 30lb propane bottle yesterday around 4:00pm an after running it yesterday afternoon and last night I now have approximately half a bottle left an it’s only 10:54 am.. Did not think this heater was going to be this terrible on propane..! To fill that 30lb propane bottle cost me 41.13 .. I even got up durning the night to shut the heater off an thought I’d be good for a while.. NOPE..! Wasn’t the case at all..! I bought the Martin Propane Direct Vent Heater MDV20VP 20000 Btu... Diff NOT IMPRESSED..! Along with the warm temps, also come high humidity. Currently +17, 18 in here with 52% humidity .. Current sq footage of my semi off grid shelter is 384sq/ft.. Yup... am NOT impressed at all..!!!
Wow! You need a wood stove! Not fun at all!
Insullation! Id invest in some R30
Insulation! Id invest in some R30
It is a ventless model. As I have said before it is ONLY used as a back up should we be away for more than a day at a time. It does cause condensation which causes black mold if not dried out quickly. Our primary source of heat is wood which dries the condensation up.
What about ventilation?
How do you prevent them from flying away??
We trim their primary flight fwathers
Feathers
This heater is a piece of crap. I bought one and it never worked.
I have one that has worked with no problems for years. It heats my house very well.
I got a dyna glo cabinet propane heater .. less than a year gotta replace thermo couple already. China made
I would get that for a back up but in Canada that would cost quite a bit if that tank only lasts a week.
That pencils out to be a heck of a lot cheaper than frozen broken pipes, me thinks. Besides if it is for "back up" how long are you expecting to be running on back up?
@@OlTrailDog I would use it when if I get sick and can't cut wood perhaps put it on before I go to bed if I want to sleep in.
These are very unhealthy and should be illegal! If it doesn’t vent exhaust outside you don’t want it. Buy a cheap pellet stove and it will pay for itself. You can run it on a small generator in an emergency.
Well said. These are the worst heaters you can pit anywhere. They may heat up a room but the health risks are too high.
dont forget that the only heater for enclose building is kerozene heater
True about kerosene, but this particular blue flame Dyna-Glo is rated for ventless indoor heating
I have been using these heaters for a few years now I have a 500 gallon propane tank I know a lot of people push the Buddy heaters I prefer this kind I am happy with them you can't hear them run like a furnace😊
If you’re running two of these everyday, how long does the 500gallon last?
@@brockdyncatron3775 for my house about 1200 square feet I run one heater on each end of the house use less than 600 gal a year
I got a couple of these in my home for supplement heat to my electric heaters and backup heat during blackouts. Not sure why no one mentions it in their reviews but that thin sheet metal Bings, Bangs and Booms as it heats up and cools down all the time, not a big deal but I watched reviews before I bought and no one mentioned it, it startled me when it happened and be prepared folks.
But isn't burning?
Nice that you didn't mount it really high like most people do
Do you have to lug that 100 pounder to town to fill it?
Not vented ??
Very nice!
Do you have to crack a window the the blue flame version?
No, if oxygen is depleted in the room the pilot is designed to shut off.
Helped me fix mine wasn't holding the gas long enough appreciate it
The Blue Flame is more a convection heater but they do have the radiant ones with the ceramic heaters. I’ve had both and the radiant heaters are much better imo. They do put off a smell and lots of moisture so it’s advisable to crack a nearby window.
Does the blue flame smell like the ceramic ones?
do you have a separate system for cold water
In really cold weather you wont use the last 10-13% of your gas if the tank is sitting in the snow.
Be careful running a NO VENT heater as they create moisture. Moisture will start to drip and cause dangerous mold.
Cn u give more details please
NO VENT wall furnaces are not for well insulated areas as they need fresh air...IF no outside air is coming in they will create humidity and walls will start to get mold....Lots of videos on CZcams on this and when buying a non vented heater it will even warn you in the instructions and on the box @@monanddom5933