Replacement Ac transformer 430v /230v melted and shorted.
Replacement Ac transformer 430v /230v melted and shorted.
zhlédnutí: 78
Video
Chiller annual shut down Tube cleaning progress.....
zhlédnutí 149Před 12 hodinami
Chiller annual shut down Tube cleaning progress.....
Daikin FCU blower bearing dismantle and installed new bearing replacement work...
zhlédnutí 99Před dnem
@plushvac please subscribe my channel 🙏 Daikin chilled water FCU blower bearing dismantle and installed new bearing replacement work... thanks for see my video 🙏 czcams.com/play/PL5VXp30dIypbHGJtOtM8vencsiMDiaVLW.html czcams.com/play/PL5VXp30dIypZjIhuwxukp2skuJp8lBOrG.html czcams.com/play/PL5VXp30dIypY0U19Fn4JMdfNljFbfhEcU.html
Daikin inverter unit error code -E7
zhlédnutí 150Před 14 dny
@plushvac please subscribe my channel 🙏 Daikin inverter unit error code -E7 in this video condenser unit motor wire burn and error code E7. replaced motor and test run system. thanks for see my video 🙏 czcams.com/play/PL5VXp30dIypbHGJtOtM8vencsiMDiaVLW.html czcams.com/play/PL5VXp30dIypZjIhuwxukp2skuJp8lBOrG.html czcams.com/play/PL5VXp30dIypY0U19Fn4JMdfNljFbfhEcU.html
error code - E59 Mitsubishi unit VRF check and troubleshooting ...
zhlédnutí 100Před 21 dnem
Mitsubishi unit VRF error code - E59 check and troubleshooting....
Daikin fan coil unit chemical clean .
zhlédnutí 305Před 9 měsíci
@plushvac please subscribe my channel 🙏 Brand - Daikin Daikin fan coil unit chemical clean . step by step we Dismental the fcu and separate all the part , chemical clean the coil ,again put back the system normal thanks for see my video 🙏 czcams.com/play/PL5VXp30dIypbHGJtOtM8vencsiMDiaVLW.html czcams.com/play/PL5VXp30dIypZjIhuwxukp2skuJp8lBOrG.html czcams.com/play/PL5VXp30dIypY0U19Fn4JMdfNljFbf...
DAIKIN VRV 3 error code - LC
zhlédnutí 7KPřed 9 měsíci
Please subscribe my channel 🙏 In this video DAIKIN VRV 3 error code - LC thermostat blinking. Error code - LC mean Mainly pcb board problem that means main pcb board , inverter pcb, fan board and noise filter board problem in this case Daikin VRV 3 check and found condenser unit inverter board pcb wire burn and faulty. In this video briefly show you how to replace inverter pcb board. because of...
Mitsubishi fcu water leak. clean and rectify the leaking issue temporarily.
zhlédnutí 251Před 9 měsíci
Mitsubishi fcu water leak. clean and rectify the leaking issue temporarily.
Daikin error code - J5,J6,J7,J8,J9. For replace thermistor for condenser unit.
zhlédnutí 6KPřed rokem
Daikin error code - J5,J6,J7,J8,J9. For replace thermistor for condenser unit.
Daikin error code - E7. Main pcb board Burn. so check compressor winding resistance and Continuity
zhlédnutí 667Před rokem
Daikin error code - E7. Main pcb board Burn. so check compressor winding resistance and Continuity
Daikin wired thermostat BRC2E61 to find room, return air, liquid,gas temperature and error code
zhlédnutí 4,3KPřed rokem
Daikin wired thermostat BRC2E61 to find room, return air, liquid,gas temperature and error code
TOSHIBA UNIT VRF ERROR CODE - P26. COMPRESSOR SHORTED,BYPASS COMPRESSOR,SYSTEM RUN EMERGENCY MODE.
zhlédnutí 7KPřed rokem
TOSHIBA UNIT VRF ERROR CODE - P26. COMPRESSOR SHORTED,BYPASS COMPRESSOR,SYSTEM RUN EMERGENCY MODE.
ON coil temperature and OFF Coil temperature.
zhlédnutí 3,3KPřed rokem
ON coil temperature and OFF Coil temperature.
Daikin new vrv unit for old VRV III condenser unit.
zhlédnutí 208Před rokem
Daikin new vrv unit for old VRV III condenser unit.
Daikin error code - E3.CU Heat exchanger Badly choked.
zhlédnutí 933Před rokem
Daikin error code - E3.CU Heat exchanger Badly choked.
Mitsubishi VRF FCU not cool, check and found main pcb board problem
zhlédnutí 3,8KPřed rokem
Mitsubishi VRF FCU not cool, check and found main pcb board problem
Calculate BTU for new aircon to my room and living room.
zhlédnutí 98Před rokem
Calculate BTU for new aircon to my room and living room.
Megger insulation resistance testing for 3 phase induction motor
zhlédnutí 43Před rokem
Megger insulation resistance testing for 3 phase induction motor
(YORK CHILLER) Brief tell about York Air-cool chiller.
zhlédnutí 73Před rokem
(YORK CHILLER) Brief tell about York Air-cool chiller.
DAIKIN Installed VRV A new condenser unit for OLD VRV 3 FCU.
zhlédnutí 213Před rokem
DAIKIN Installed VRV A new condenser unit for OLD VRV 3 FCU.
Daikin Air-cool chiller alarm EXV MODULE PROBLEM.
zhlédnutí 1,1KPřed rokem
Daikin Air-cool chiller alarm EXV MODULE PROBLEM.
Daikin error code - E5 inverter pcb board compressor problem emergency mode run standard compressor
zhlédnutí 12KPřed rokem
Daikin error code - E5 inverter pcb board compressor problem emergency mode run standard compressor
check with AHU VSD , AHU actuator work or not.
zhlédnutí 542Před rokem
check with AHU VSD , AHU actuator work or not.
You should eliminate the corrosion from impeler
How much cost for eexv driver bro ????
sorry bro,I don't know cost of eexv,
Why wouldn't you want the low side to drop when the compressor is engaged? 80 psi seems high though, isn't it ? (I don't know commercial HVAC pressures)
hi guys , condenser unit main breaker trip, after turn on the breaker, but condenser unit cannot start, system stable time pressure ok, so we top up gas R410 , after few minutes system can start. but pressure very faster drop to blew 80 psi. here suspect gas leak from system. after top up gas , condenser unit back to normal.pressure and amps is ok.but need to find the gas leak.
It is harmful error
It could be the pcb not the fan... 😂😂😢
Sir how much k oms
Abe hindi bol le angreg😊
So, inverted pcb board kompressor is broken ??
Weaaaa😅
After bypass again how back to normal mode?
Ur from ??
What cause this eev board not working can you please explain it
Eexv board became faulty, eexv valve not work. So totally chiller not work.
@@plushvac so we can't repair the eev board?
I don't know can repair or not, we replaced new eexv board.
Zabar dast bhai good knowledge
Very good 💯
Thanks
What to do first test running or auto gas charging
VRV first u test run time. Have Error code u3-10. Need to run auto gas charging. After run testode.
Super brother
Thank you
Merhaba Test modunu nasil calistirabilirim
Kepala nenek kau fcu
Bro can you know pcb testing
Hlo
I ask questions..wat is model# that unit sir? Can u show?.
VRV 3 rxq10pay
❤❤❤❤❤❤
Thanks
Excellent work
Thanks
Hello , i need paper please (02:42)
Sorry,I no have any paper
Pepper will do instead.
Sorry I no have
what does fault code E0 mean? Please explain
Outdoor unit need to check one by one
Please check compressor and pcb board
Bhai Hindi me total error code ka solution bataye
VRV 3 Multi outdoor units emergency setting plz share...
Ohm out the eev, check that both the plug and the eev are properly seated and not grounding out. Otherwise, leave the breaker off for 15-20 minutes (don't rush it, believe me!) Make sure everything is tight and turn it back on.
Hi, my ahu actuator also same problem (automatically open close), but my site don't have bms or vfd system. operate by tharmosted. What is the problem about this issue? Now how I can check for this problem? Plz tell me
Qual seria o defeito , válvula de expansão?
how to lock the remote
Did you got any solutions.
Bagaimana cara ngatasinnya
San nkakabile ng pyesa
Fan pcb ya fan moter
Inverter pcb
what is the solution?
Nice 😎
Thanks
czcams.com/video/Q6HlOzAjRJQ/video.html
Negro capacitor
Hello Bro
Hi bro
@@plushvac Bro you working in Singapore?
@@acmv6783 no
Toshiba vrf me indoor error ko kaise bypass karte hai outdoor unit se
I don't know Hindi language
Kya aapka no. Mil sakta h aap kis city se ho
Helpful video
Thanks
How to check expansion valve reading in this remote
👍👍👍
Thanks
Very nice
Thanks
Bro pls upload Daikin remote feild setting videos
Ok
En français svp
😍😍😍👌👌👌
Thanks
Thank you bro all the best
Thanks bro.