Dare to probe your ultrasound probes
Damaged or dirty ultrasound probes have been linked to infections and injuries among patients.
In this video, Cori Ofstead, MSPH, discusses strategies for identifying and addressing ultrasound processing and maintenance issues.
This video covers content included in Ofstead & Associates’ free, 1-hour, CE-eligible webinars:
- “Ultrasound probes 101: Challenges with probe processing and implications for patient safety” ofstead.elevate.commpartners.com/products/ultrasound-probes-101-challenges-with-probe-processing-and-implications-for-patient-safety
- “Ultrasound probes 201: Common sense strategies for ultrasound probe quality management” ofstead.elevate.commpartners.com/products/ultrasound-probes-201-common-sense-strategies-for-ultrasound-probe-quality-management
Please like and subscribe to our CZcams channel so you don’t miss any videos!
And check out the other resources listed in this video, including:
Ofstead CZcams videos:
- Tools used for visual inspection czcams.com/video/mKe_jLn3W1I/video.html
Peer-reviewed literature:
- Chen et al. A multicenter study on the effects of different methods of disinfecting medical external-use ultrasound probes. AJIC. 2023. www.ajicjournal.org/article/S0196-6553(23)00410-8/pdf
- Carrico et al. Ultrasound probe use and reprocessing: Results from a national survey among U.S. infection preventionists. AJIC. 2018;46(8):913-920. www.ajicjournal.org/article/S0196-6553(18)30255-4/fulltext
Ofstead & Associates, Inc. has published articles in peer-reviewed journals on a variety of topics, which are searchable here:
pubmed.ncbi.nlm.nih.gov/?sort=date&term=Ofstead+CL&cauthor_id=36075293
--
Ofstead & Associates, Inc. specializes in designing and conducting real-world research to validate healthcare guidelines, treatments, product claims, and processes of care. Our critical insights deliver actionable solutions for multiple stakeholders. We are experts at performing customized translational research and developing tailored output for a diverse group of clients. To learn more about our work, check out our website:
www.ofsteadinsights.com
zhlédnutí: 670

Video

Use SBAR for resource requests
zhlédnutí 121Před 6 měsíci
New standards and guidelines are coming out all the time, and that often means more equipment, more processes, and more work for frontline personnel. In this video, Krystina Hopkins, MPH breaks down the SBAR (Situation, Background, Assessment, Recommendation) approach to communication with decision-makers and discusses numerous tools and resources for crafting requests . The customizable SBAR t...
Suctions and shavers - oh my!
zhlédnutí 741Před 8 měsíci
We’ve found lots of icky stuff when we inspect endoscopes with borescopes, but what about the lumens of surgical instruments? Krystina Hopkins, MPH, describes findings from borescope investigations of suction tips and arthroscopic shaver handpieces. This video covers content included in Ofstead & Associates’ free, 1-hour, CE-eligible webinar called “Beyond endoscopes: Visual inspection of surgi...
Sterile processing issues in outpatient urology clinics
zhlédnutí 803Před rokem
Recently, urological endoscopes have been designated as a “high-risk” for inadequate processing and potential germ transmission. In this video, Cori Ofstead, MSPH, reflects on her experiences auditing outpatient urology clinics and the challenges faced by personnel responsible for processing scopes, probes, and stainless-steel instruments in these settings. Please like and subscribe to our chan...
Inspection of surgical instruments on the “clean” side of sterile processing
zhlédnutí 6KPřed rokem
Borescope examinations of endoscope channels and ports is a standard and guideline-recommended practice. But what about the inner surfaces of stainless-steel surgical instruments? Cori Ofstead, MSPH, outlines four methods of lumen inspection for surgical instruments and the concerns raised by current practices. Please like and subscribe to our channel so you don’t miss any videos! Check out the...
Splash generation in decontamination units
zhlédnutí 1,7KPřed rokem
Cleaning medical devices is a wet, messy process. In this video, Krystina Hopkins, MPH outlines the findings from two recent real-world studies that show sterile processing technicians are getting drenched from head to toe and she calls for new solutions to protect workers. This video covers content included in Ofstead & Associates’ free, 1-hour, CE-eligible webinar called “Making a splash: Con...
“Hang time” limits for flexible endoscopes
zhlédnutí 6KPřed rokem
The acceptable length of time for storage between endoscope processing and patient use is controversial and depends on a lot of assumptions about processing effectiveness. In this video, Cori Ofstead, MSPH lays out the issues around endoscope “hang time” and provides some possible solutions. This video covers content included in Ofstead & Associates’ free, 1-hour, CE-eligible webinar called “Th...
Alcohol and endoscope drying: To flush or not to flush
zhlédnutí 937Před rokem
Perspectives on the use of alcohol to aid endoscope drying are shifting. In this video, Krystina Hopkins, MPH talks about new evidence that upends assumptions about the effectiveness of alcohol in inhibiting microbial growth and facilitating drying of endoscope channels. This video covers content included in Ofstead & Associates’ free, 1-hour, CE-eligible webinar called “The endoscope drying im...
Common defects found with borescopes
zhlédnutí 1,5KPřed rokem
Studies show that 100% of flexible endoscopes at sites that haven’t been conducting visual inspection have defects, and that includes endoscope interiors. In this video, Cori Ofstead, MSPH, walks through common defects you might find inside your endoscopes when you begin using borescopes. This video is an excerpt from Ofstead & Associates’ free, 1-hour, CE-eligible webinar called “Visual inspec...
Searching the FDA MAUDE database
zhlédnutí 1,8KPřed rokem
The FDA MAUDE database contains reports of adverse events associated with medical devices, including malfunctions, injuries, and outbreaks. In this video, Abby Smart, MPH, provides a how-to on using the MAUDE database to support purchasing and decision-making. This video is an excerpt from Ofstead & Associates’ free, 1-hour, CE-eligible webinar called “Uncovering device adverse events to improv...
Tools used for visual inspection
zhlédnutí 694Před rokem
Standards and guidelines have made stronger recommendations for visual inspection using lighted magnification, and studies support the need for thorough visual inspection. In this video, Abby Smart, MPH, breaks down tools available for inspecting flexible endoscope interiors and exteriors. This video is an excerpt from two Ofstead & Associates’ free, 1-hour, CE-eligible webinars: - “Visual insp...
Endoscope Anatomy
zhlédnutí 20KPřed rokem
With standards requiring visual inspection of all flexible endoscopes during processing, it’s important to recognize that every type of endoscope is a little bit different. In this video, Abby Smart, MPH will go over basic components of various models of endoscopes, including bronchoscopes, urology scopes, GI scopes, and specialty scopes. This video is an excerpt from two Ofstead & Associates’ ...
Common defects on endoscope exteriors
zhlédnutí 6KPřed rokem
Common defects on endoscope exteriors
Residual contamination: Soil, bioburden, and biofilm
zhlédnutí 681Před rokem
Residual contamination: Soil, bioburden, and biofilm
Cleaning verification tests and tools
zhlédnutí 1,1KPřed rokem
Cleaning verification tests and tools
Residual moisture in flexible endoscopes: Ofstead study profile
zhlédnutí 435Před rokem
Residual moisture in flexible endoscopes: Ofstead study profile
Drying and drying verification tools
zhlédnutí 216Před rokem
Drying and drying verification tools

Komentáře

  • @ofsteadinsights9726
    @ofsteadinsights9726 Před měsícem

    Link to full paper: pubmed.ncbi.nlm.nih.gov/38495009/

  • @tonybologna9071
    @tonybologna9071 Před 2 měsíci

    I see gastroscope and duodenoscope but don’t the EGD scope cover all that?

  • @tilahunfitale6170
    @tilahunfitale6170 Před 2 měsíci

    thanks

  • @cinateb_com2
    @cinateb_com2 Před 3 měsíci

    💯🤩👏👏👏

  • @ofsteadinsights9726
    @ofsteadinsights9726 Před 3 měsíci

    Click the link to read the published AJIC article on this study: www.ajicjournal.org/article/S0196-6553(24)00103-2/fulltext

  • @ofsteadinsights9726
    @ofsteadinsights9726 Před 5 měsíci

    Link to original article: www.journalofhospitalinfection.com/article/S0195-6701(23)00342-0/abstract

  • @user-jk6sh3el3y
    @user-jk6sh3el3y Před 7 měsíci

    Thanks so much Informative video Im cssd Endo technologist

  • @user-jk6sh3el3y
    @user-jk6sh3el3y Před 7 měsíci

    Thanks so much Informative video I'm cssd & Endo technologist

  • @queenofspiders
    @queenofspiders Před 7 měsíci

    I’m going for an interview to become a QC tech for endoscopes and this really helped me learn more about them. Thank you!

  • @nosensenologic3355
    @nosensenologic3355 Před rokem

    Very informative thank you S

  • @protector7886
    @protector7886 Před rokem

    Would you mind posting the devices and/or setup you use to get these images?

    • @ofsteadinsights9726
      @ofsteadinsights9726 Před rokem

      During our studies, we used bench-mounted and hand-held magnifiers provided by Healthmark. Some external images were captured using an M8 Lenovo Android tablet. We also used borescopes from Clarus, Healthmark and Steris (Cantel/Medivators) to capture external images.

  • @protector7886
    @protector7886 Před rokem

    For the BF-1TH190 Bronch scope @6:30. Is that a Stiffness/Tensioner dial or a Rotation Ring?

  • @timc924
    @timc924 Před rokem

    Thank you for posting the very informative series. Can you recommend a particular model to cover all flexible endoscopes- my unit oversees reprocessing of the full range and a Boroscope rig to cover all would be a great advantage as we have a mixture of new and legacy inventory in our fleet.

    • @ofsteadinsights9726
      @ofsteadinsights9726 Před rokem

      First, we do not endorse any particular product. Second, for our published studies and webinars, we have used borescopes from Healthmark, Clarus and Steris. You will likely need two different diameter cameras-- a large one that would be around 2 mm and a smaller one less than 1 mm. Some units allow for plug-n-play of different camera sizes.

  • @MRG3RH4RD
    @MRG3RH4RD Před rokem

    Scariest stuff yet if you think about it!

  • @kevinanderson7593
    @kevinanderson7593 Před rokem

    Great visuals that everyone that processes scopes should be aware of and view regularly. Nicely done as always!