(WATER TREATMENT PRODUCTS)
(WATER TREATMENT PRODUCTS)
  • 8
  • 7 652
SWIMMING POOL DOSING SYSTEM - PH - FREE CHLORINE CALIBRATION - KONTROL K800
SWIMMING POOL DOSING SYSTEM - KONTROL K800 - MULTIPARMETER CONTROLLER WITH PH PROBE / CHLORINE PROBE - EXPLAINATION ABOUT CALIBRATION OF THE PH & CHLORINE PROBE
zhlédnutí: 5 063

Video

TM DIGITAL SETTINGS - ENZYME DOSING PUMP - GREASE TRAP
zhlédnutí 303Před 2 lety
TIMER BASED ENZYME DOSING PUMP FOR GREASE TRAP APPLICATION. IT HAS PUMP ON-OFF - TIMER / WEEKLY TIMER - EASY DIGITAL TIMER SETTING - CLOCK SETTINGS - AVILABLE BOTH POWER AND BATTERY VERSION
FCL CHLORINE PROBE GEL FILLING
zhlédnutí 89Před 2 lety
FREE RESIDUAL CHLORINE PROBE - POTENTIOSTATIC PROBE - INTIAL ELECTROLYTE GEL FILLING - COMMISSIONIONG OF CHLORINE PROBE - APPLICATION: DOMESTIC WATER CHLORINATION - WORKING IN WIDE RANGE OF PH
CSV TO EXCEL CONVERTION
zhlédnutí 15Před 2 lety
How to convert .csv data to excel file
FAST MIXER INSTALLATION
zhlédnutí 25Před 3 lety
Installation of fast mixer suitable for cylindrical tank. shaft available in PVC coated version, PTFE coated version and SS316L. Both single phase and three phase motor available.
Drain mini - Grease Trap Enzyme dosing pump
zhlédnutí 1,5KPřed 3 lety
Drain mini - Power version. Grease trap enzyme dosing. timer based enzyme dosing pump. Pump has daily on-off timer. timer setting is customisable based on customer requirements.
Chilled water dosing system K40
zhlédnutí 695Před 3 lety
chilled water dosing system with kontrol 40. configuration of controller for aur dosing pump automatic operation based on conductivity setpoint. calibration of conductivity Probe with Kontrol 40

Komentáře

  • @dileepnk3609
    @dileepnk3609 Před 9 měsíci

    hi

  • @nithishkumar9226
    @nithishkumar9226 Před 9 měsíci

    600 is enough for Chiller water system????

  • @rizwanali-kv5xt
    @rizwanali-kv5xt Před rokem

    if forget password .then to open setting.

  • @rangalakshan2775
    @rangalakshan2775 Před 2 lety

    hello can you explain about second point. need to put 0ppm in every time??

    • @watertreatmentproducts3177
      @watertreatmentproducts3177 Před 2 lety

      Yes. Second point calibration is like zero calibration. After closing the water flow wait for 60 to 120 sec and then feed 0ppm --->press Enter button

    • @james230887able
      @james230887able Před rokem

      So no need for any standard solutions?

  • @lexley1234
    @lexley1234 Před 2 lety

    Hi do you have one document to see how program the pump i’vee looking for it but i didn’t find it