![Lucia Tou](/img/default-banner.jpg)
- 26
- 149 215
Lucia Tou
Registrace 10. 07. 2017
This is Lucia, we are manufacture for pH EC TDS ORP Salinity meter, do meter and other water quality tester since 2009, wiil show our device wroking video, factory video. Welcome to order.
BLE-C600 pH Calibrate at 6.86/4.00/9.18 pH CAL pH calibration 6.86
Please use 6.86 4.00 9.18 pH solution
Lucia 0086 13166576796
Skype: toulucia2017
lucia@yinmikbest.com
Lucia 0086 13166576796
Skype: toulucia2017
lucia@yinmikbest.com
zhlédnutí: 6 762
Video
EZ-9910 pH calibrate at 6.86/4.00/9.18 pH CAL pH calibration 6.86
zhlédnutí 1,5KPřed 2 lety
Please use 6.86 4.00 9.18 pH solution Lucia 0086 13166576796 Skype: toulucia2017 lucia@yinmikbest.com
Monitor BLE-3178 pH calibrate at 6.86/4.00/9.18 pH calibration 6.86 pH CAL
zhlédnutí 289Před 2 lety
Open the YINMIK APP, Setting- pH buffer- choose 6.86 4.00 9.18 (Asia Standard) Use 6.86 4.00 9.18 pH solution Then calibrate the device as shown in the video. If choose 7.00 4.00 10.01 (EU standard), please use 7.00 4.00 10.01 calibration solution 7.00 4.00 10.01 calibration procedure is the same as the 6.86 4.00 9.18 calibration procedure; Lucia 0086 13166576796 Skype: toulucia2017 lucia@yinmi...
EZ-9909SP pH Calibrate at 6.86/4.00/9.18 pH CAL pH calibration 6.86
zhlédnutí 7KPřed 2 lety
Please use 6.86 4.00 9.18 pH solution Lucia 0086 13166576796 Skype: toulucia2017 lucia@yinmikbest.com
Floating Pool Monitor BLE-YC01 pH calibration at 7.0/4.0/10.0 pH calibrate 7.00 pH CAL
zhlédnutí 6KPřed 2 lety
Open the YINMIK APP, Setting- pH buffer- choose 7.00 4.00 10.01 (EU standard), please ues 7.00 4.00 10.01 calibration solution Then calibrate the device as shown in the video. If choose 6.86 4.00 9.18 (Asia Standard) Please use 6.86 4.00 9.18 pH solution 6.8/4.0/9.1 calibration procedure is the same as the 7.0/4.0/10.0 calibration procedure; Lucia 0086 13166576796 Skype: toulucia2017 lucia@yinm...
Floating Pool Monitor BLE-YC01 pH calibration at 6.8/4.0/9.1 pH calibrate 6.86 pH CAL
zhlédnutí 3,2KPřed 2 lety
Open the YINMIK APP, Setting- pH buffer- choose 6.86 4.00 9.18 (Asia Standard) Use 6.86 4.00 9.18 pH solution Then calibrate the device as shown in the video. If choose 7.00 4.00 10.01 (EU standard), please ues 7.00 4.00 10.01 calibration solution 7.0/4.0/10.0 calibration procedure is the same as the 6.8/4.0/9.1 calibration procedure; Lucia 0086 13166576796 Skype: toulucia2017 lucia@yinmikbest.com
Floating Pool Monitor BLE-YC01 pH CL orp meter operate to Bluetooth connect yinmik app
zhlédnutí 8KPřed 2 lety
Lucia 008613166576796 Skype: toulucia2017 lucia@yinmikbest.com #Pool
completed BLE-9909 pH calibration; 5 IN 1 pH Meter calibrate at 6.86 4.00 9.18 three points
zhlédnutí 1,1KPřed 2 lety
How to calibrate pH Meter at 6.86 4.00 9.18 point? Manufacturer for pH ec tds salint orp hydrogen meter; dissolved oxygen meter; Soil ec moisture meter since 2010; Lucia Skype: toulucia2017 Whatsapp: 86 13166576796 Email: lucia@yinmikbest.com
C-200 Hydrogen ORP 256mV calibration; ORP CAL; ORP meter calibration;
zhlédnutí 4,6KPřed 2 lety
How to calibrate ORP Meter at 256 mV point? Manufacturer for pH ec tds salint orp hydrogen meter; dissolved oxygen meter; Soil ec moisture meter since 2010; Lucia Skype: toulucia2017 Whatsapp: 86 13166576796 Email: lucia@yinmikbest.com
C-600 ORP 256mV calibration for 7 in 1 pH salinity orp ec tds meter;
zhlédnutí 7KPřed 2 lety
#ORP Calibration# ORP 256 mV calibrate; Oxidation-reduction potential C-600 7 in 1 water quality pH ec tds salinity orp temp meter calibration video Skype: toulucia2017 Whatsapp: 86 13166576796 We are manufacturer for pH ec tds salinity meter, dissolved oxygen meter, soil ec moisture meter since 2010.
BLE-9909 ec 1413uS/cm calibration, conductivity CAL
zhlédnutí 2,5KPřed 2 lety
How to calibrate ec at 1413 μS/cm point; Email: lucia@yinmikbest.com Whatsapp 86 13166576796 Skype: toulucia201
BLE-9901 pH calibration, pH calibrate at 6.86 4.00 9.18 three points pH CAL
zhlédnutí 3,2KPřed 2 lety
How to calibrate pH meter? The correct calibration procedure is important to the accuracy of pH. Newest BLE-9901 3 in 1 pH tds temp meter; the calibration procedure of EZ-9901 is same as BLE-9901. Whatsapp: 008613166576796 Skype: toulucia2017 Email: lucia@yinmikbest.com
DO9100 Dissolved oxygen meter 100% calibration in air; DO Meter calibrate
zhlédnutí 12KPřed 2 lety
How to use dissolved oxygen meter? How to calibrate dissolved oxygen meter in air? 100% DO Meter calibration video Whatsapp: 86 13166576796 Skype: toulucia2017 Email: lucia@yinmikbest.com
P-3 pH calibration; pH and temperature meter calibration at 6.86 4.00 9.18 or 7.00 4.00 10.01
zhlédnutí 373Před 2 lety
BLE-P-3 calibration video at 6.86/4.00/ 9.18 or 7.00 /4.00/10.01; you can choose two calibration mode pH and Temperature water quality test meter; pH meter need to be calibrated regulary; The correct calibration procedure will make your pH meter more accurate‘; Whatsapp: 86 13166576796 Skype: toulucia2017 Email: lucia@yinmikbest.com
Newest BLE-9909 pH calibration; 5 in 1 Salt/EC/TDS/pH meter calibrate at 6.86 4.00 9.18 three points
zhlédnutí 4,7KPřed 2 lety
BLE-9909 calibration video on 6.86 4.00 9.18 5 in 1 pH ec tds salinity Temperature water quality test meter; pH meter need to be calibrated regulary; The correct calibration procedure will make your pH meter more accurate‘; Whatsapp: 86 13166576796 Skype: toulucia2017 Email: lucia@yinmikbest.com
7 in 1 pH/ec/tds/salinity/S.G/ORP/Temperature meter C-600 pH meter calibrateion with 4.00 6.86 9.18
zhlédnutí 19KPřed 3 lety
7 in 1 pH/ec/tds/salinity/S.G/ORP/Temperature meter C-600 pH meter calibrateion with 4.00 6.86 9.18
C-600 combo 7 in 1 ec calibration 1413 uS/cm calibration pH orp salinity ec tds temp meter
zhlédnutí 2,4KPřed 4 lety
C-600 combo 7 in 1 ec calibration 1413 uS/cm calibration pH orp salinity ec tds temp meter
ez9909SP ec 1413 uS/cm calibration video; multifunction 5 in 1 pH ec tds temp meter; conductivity
zhlédnutí 10KPřed 4 lety
ez9909SP ec 1413 uS/cm calibration video; multifunction 5 in 1 pH ec tds temp meter; conductivity
ez9908 ec 1413 uS/cm calibration video; multifunction 4 in 1 pH ec tds temp meter;
zhlédnutí 2,5KPřed 4 lety
ez9908 ec 1413 uS/cm calibration video; multifunction 4 in 1 pH ec tds temp meter;
ez9902 ec 1413 uS/cm calibration video; multifunction 3 in 1 pH ec temp meter; conductivity calibrat
zhlédnutí 2,5KPřed 4 lety
ez9902 ec 1413 uS/cm calibration video; multifunction 3 in 1 pH ec temp meter; conductivity calibrat
ez9901calibration; ec tds 1413uS/cm ppm calibration 3 in 1 pH tds temp meter calibration;
zhlédnutí 2KPřed 4 lety
ez9901calibration; ec tds 1413uS/cm ppm calibration 3 in 1 pH tds temp meter calibration;
pH calibration at 6.86 4.00 9.18 for pH03 pH meter P-3 tester
zhlédnutí 250Před 4 lety
pH calibration at 6.86 4.00 9.18 for pH03 pH meter P-3 tester
pH calibration video; multifunction 4 in 1 pH ec tds temp meter
zhlédnutí 994Před 4 lety
pH calibration video; multifunction 4 in 1 pH ec tds temp meter
Hi, ich messe mit dem Smart Pool monitor 0.1mg/l die üblichen Teststreifen zeigen ein Ergebnis von 0.3mg/l. Welches Ergebnis ist richtig? MfG Michael
What's the cost, price?
is this accurate ?
Is talking illegal in a video?
Hi . I have got this meter can you get spare tips with the membrane in for these . I only have 1 left . Thanks.
Tôi cũng sử dụng bút này. Nhưng mỗi lần cal thì bút đều cal ở vị trí 6.86. Nó không bao giờ cal ở mức 4.0 hay 9. Có ai giúp tôi giải đáp không?
The electrode is broken
Are you calibrating once at each PH or do you have to go back around and do it again? Can you calibrate in any order? So new to this! Thank you!
The first calibration point must be 7.0pH calibration point, and then calibrate 4 or 10
@@luciatou9203 Lucia, I have another question. How do we test the TDS? Do we need another type of solution? I appreciate any help on this. Thank you!
I don’t have my buffer powder anymore. Is there still a way to calibrate it?
The calibration powder is standard in the world, can find in the market
@@luciatou9203 oh ok👍🏼
What does MV mean or represent? Because I don't think they use MV as a measurement here in South Africa ? Because I want to calibrate it to measure the Chlorine levels in pool?!
mV is the measurement unit of ORP. The ORP value can reflect the level of residual chlorine and has a positive relationship. The OPR value of a general swimming pool is 650-750mV.
@@luciatou9203 Thanks for confirming. My C-600 Tester seems to be working great so far.
Hi Lucia, Does this device have the ability to test for Chlorine? And is there any way I Can use it to test for Alkilinty as well?
This model can test free chlorine. can't test the alkilinty
@@luciatou9203 cool! thanks for confirming!
Can the C-600 also test for Chlorine? Because I've read that the ORP is a measurement for checking Chlorine?
I just bought the C-600 7in1 multifuntion water quality tester to test my pool water with. But can't seem to find any clear instructions in the box? And does this test for Chlorine as well? I need pH, alkilinty and Chlorine?
this model is pH EC TDS ORP Salinity S.G temperature, don't have chlorine and alkilinty
@@luciatou9203 oh okay! Thanks for your swift response. Noted! Maybe you guys can try making a tool where you can check Total Alkilinty, Chlorine and PH levels. There is aahpr market in the world for it. If it's not too expensive. Just a thought.
@@luciatou9203Doesn't the "ORP" value used for Chlorine testing as well? Oxidation-reduction potential (ORP) is a solid measurement to determine the general water quality of a swimming pool. It provides insight into the overall chlorine level and level of sanitation (positive ORP readings in the 650-750 mV range are ideal for sanitation).?
@@debt172sop839 yes, The ORP value reflects the level of residual chlorine. 650-750mV is ideal range
@@luciatou9203 Awesome Thanks! :) So I can use the C-600 for check the Chlorine levels in my pool! Happy days :)
I have this make instrument, that's Not User friendly, Instead Go for Hanna Instruments
You can choose the Hanna instrument you like
@@luciatou9203 Yes, I bought Hanna Instrument 4 months ago and it's accurate and easy to Calibrate
I calibrate the first 7.0 pH as shown on video, but when I put the sensor on 4.0 pH solution, it down only to 6.4 on display. And when I put it on 10 pH solution, it goes only until 7.6. Which means that I can't calibrate the 4.0 and 10.0 measurements. Is my sensor damaged? There is any way to reset the sensor?
This means that the electrode is broken. You need to contact your supplier to replace the electrode.
Love the results of this pen
Where can we find a PDF for this device ? Also : The Bluetooth and app doesn't work on Android. It stays frozen. Already tried the troubleshooting steps. And how do you get TDS data to show ?
Terimakasih🤝
it's nothing
Что за глухой канал!
Do we need to calibrate it before use?
It is recommended to calibrate the pH before first use
How & where do I see the chlorine?
THANK You, Lucia! 🤩 description: 1) power on tds-meter 2) put it on solution 1413 uS/cm (706 ppm) 3) press MODE to select uS/cm (or PPM) 4) press and HOLD MODE/CAL button for 6 sec, then release 5) press UP / DOWN buttons ( "hold/temp" for UP, "mode/cal" for DOWN) and SET 1413 6) wait for flashing 3 times "1413" 7) Calibration Complete!
Merci beaucoup
Hi lucia. How can i calibrate the salinity?
Salinity and EC are set in a relationship. Generally, after calibrating the EC, the salinity will be automatically calibrated.
Hello, manual says use 250ml of water per beaker. In the video no more than 100ml is used. Which is correct?
It is to dissolve the powder with 250mL. But it does not mean that 250mL of solution must be used for calibration, the remaining uncontaminated calibration solution is stored for later use
The instructions say it is calibrated at the factory
Hello How to calibrate the EC and ORP?
EC use 1413μS/cm and 12.88 mS/cm calibration solution; ORP use is 222mV calibration solution
Hello How to calibrate the EC and ORP?
What solution you use for calibration?
ORP use is 256mV
@@luciatou9203como fazer o reset original de fabrica?
Turn on the meter, press ON/OFF button for 10s, it will display ----|, reset complete@@FujamParaOsMontesOficial
@@luciatou9203my model is JQ006. 10 in 1
Hi, how to reset the ph? I made some mistake. I followed the manual on how to reset ph but it doesn't work.
Hi, how to reset the ph? i mixed up the buffer solution and now my ph readings are all wrong. Thanks!
Good demo. Thanks!
TENGO UN EQUIPO IGUAL, ¿QUE METODO USO PARA DETERMINAR ORP EN SUELOS?
THIS device only for testing water, can't test soil
@@luciatou9203 Si se hace mediante extracto de saturación y un filtrado de la muestra?
Colete a amostra de solos e adicione água destilada. Homogeinize. Depois meça o ph da solução
Ni hao. Pentru sare trebuie calibrat aparatul?? Thank you
It has been calibrated before leaving the factory, and it does not need to be calibrated within half a year
Una pregunta,sabrias decirme porque no consigo conectarlo?.no apsrece en mi tlf.
Hi! I hope you can help me, I'm a little confused on how to calibrate my ph/ec/tds tester. I have EZ 9910 model, in the instruction it says that I needed 1413, 12.88 and 111.8 buffer solution to calibrate my tester, but in your video you only used 1413. Are the 2 other solutions not needed?
Generally, the products have been calibrated for EC before leaving the factory and can be used directly. If you require high accuracy or use it for half a year, you need to recalibrate the EC. You can choose a calibration point close to your test solution for calibration. It is not necessary to calibrate all three points. Once the EC is calibrated, TDS and salinity are also calibrated.
Thank you for your response!
hi Lucia. I have a question for you. i bought the item and opened it to try. However, the ph value is always 0, although the rest shows itself. What should i do?
If you put the probe into the calibration solution or any other liquid, it show always 0, that means the probe is broken; If the instrument show 0 in the air, it is normal
Hello, I have a newbie question about the electrolyte. If I use the device daily for, say 15 days Ina row, should I remove and throw out the electrolyte everyday after using it, or can I leave the electrolyte in place? I'm afraid I'll have to use and buy a lot of electrolyte if I need to remove it after each measuring session
If your measurement results are within the error range, you don't need to replace the electrolyte every time you use it.
@@luciatou9203 Thank you. And can keep it in place (inside the probe, in contact with the electrode), or should I remove it and store it elsewhere, and dry the electrode?
@@TheLaurentPetit When not in use for a long time, clean the sensor, replace it with new electrolyte, and save it.
@@luciatou9203 thank you!
Привет. Спасибо)
Ola, esse sistema pode enviar informaçoes via wifi?
This model via bluetooth, can't wifi
How to calibrate CL?
After calibrating pH and ORP, CL is automatically calibrated
@@luciatou9203 Thank you. I already calibrated ph and orp. but sometimes CL doesnt show correct. just if has a lot cl on the water.
Hi lucia , sorry im confusing. This uscm got 3 bottle right? It is direct tu use into the bottle? No need to mix with distilled water? Thanks in advance lucia ❤
It is liquid in the bottle, can use it directly into the bottle, don't need to mix with distilled water
How do you program EC?
Hi! thanks for the video. I've a problem: mi ph meter is so wrong that thinks the 6.8 solution is actually 9.18. Can i reset someway? or something?
This model don't have pH reset function.
@Lucia Tou help I need new probe for mine glass broke I see it's removable can you send me link were to buy it
@nazarenoiii Same problem here!
Fail ! You put the probe in the solution wait until 60seconds pass without it changing then hold the calibration button. That's why it's changing still after you calibrate it !!!!
My do9100 hanging always what happened
The software is no so good. why can't I select the setpoint value to be calibrate ? I bought this and by mistake run calibration when device was outside. Now I place it into a tap waters (~7) and run calibration but it think I'm calibration for 10 and not 7.
You have made a mistake, calibrated the pH in the air and caused the program to be disturbed. and it cannot be corrected. pH calinration point is 4.00 6.86 9.18 or 4.00 7.00 10.01. it is standard, Calibration points cannot be set arbitrarily.
@@luciatou9203 too bad the software can't handle these error cases.
Bonjour Bien pour la vidéo,me je cherche l'instruction et comme ils faudrait-il ouvrir et comme places les pile,empossible , ouvrir cette yinmik? Merci de me rassegne!?
Спасибо за видео. Но есть проблема с калебровкай EC раствора 1413µs/cm я не понимаю когда я калебрую что далжно показать на моём приборе EC он колебруется с отвёрткой? Помогите и какие значения должны быть на протяжении всего роста растишек?
Why is my meter reading drop to 0.0 reading all the time
You can contact your supplier to solve it
Where to buy ec solution 3 step. For calibration?
the ec calibration solution is standard in the world, you can check it in your country
How much this costs?