Bryan Bullock
Bryan Bullock
  • 23
  • 230 670
APX6000
APX6000
zhlédnutí: 882

Video

Intubation Considerations for COVID-19 Patients
zhlédnutí 117Před 4 lety
I have received permission from Dr. Todd Jordan to share this video.
How to Re-Use an N-95 Mask
zhlédnutí 64Před 4 lety
I received permission from Dr. Jordan to share this video.
BCES Pre-Hire Video
zhlédnutí 712Před 7 lety
BCES Pre-Hire Video
Engine 5 001
zhlédnutí 158Před 7 lety
Engine 5 001
MSA G1 SCBA Care & Use Video
zhlédnutí 3,1KPřed 8 lety
MSA G1 SCBA Care & Use Video
Video 2 - Positioning Apparatus
zhlédnutí 31KPřed 8 lety
Video 2 - Positioning Apparatus
Video 1 - Safe Operation of Emergency Vehicles
zhlédnutí 41KPřed 8 lety
Video 1 - Safe Operation of Emergency Vehicles
Video 5 - Water Shuttle and Relay Pumping
zhlédnutí 66KPřed 8 lety
Video 5 - Water Shuttle and Relay Pumping
Video 4 Apparatus Inspection and Maintenance
zhlédnutí 11KPřed 8 lety
Video 4 Apparatus Inspection and Maintenance
Video 3 - Operating Fire Pumps
zhlédnutí 12KPřed 8 lety
Video 3 - Operating Fire Pumps
Anti Lock Brakes
zhlédnutí 191Před 8 lety
Anti Lock Brakes
Nozzle Reaction for Fog Nozzle
zhlédnutí 4,2KPřed 8 lety
Nozzle Reaction for Fog Nozzle
Tire Blowout
zhlédnutí 259Před 8 lety
Tire Blowout
Nozzle Reaction for Smooth Bore
zhlédnutí 6KPřed 8 lety
Nozzle Reaction for Smooth Bore
Jackson Co vs South Forsyth 1991
zhlédnutí 508Před 8 lety
Jackson Co vs South Forsyth 1991
Stryker Power-PRO XT Stretcher
zhlédnutí 18KPřed 8 lety
Stryker Power-PRO XT Stretcher
How to Calculate Gallons Per Minute - Barrow Co. Emergency Services
zhlédnutí 30KPřed 9 lety
How to Calculate Gallons Per Minute - Barrow Co. Emergency Services
How Air Brakes Work - Barrow Co. Emergency Services
zhlédnutí 282Před 9 lety
How Air Brakes Work - Barrow Co. Emergency Services
How to Calculate Friction Loss - Barrow Co. Emergency Services
zhlédnutí 6KPřed 9 lety
How to Calculate Friction Loss - Barrow Co. Emergency Services

Komentáře

  • @justinshores7079
    @justinshores7079 Před měsícem

    8:00

  • @gregliautaud1474
    @gregliautaud1474 Před 3 měsíci

    Why use 1.57? There is no device on any pumping vehicle that can be read to a hundredth. 1.5 would be totally adequate.

  • @GeorgeSmith-lx7xg
    @GeorgeSmith-lx7xg Před 5 měsíci

    thank you good video

  • @Battalionchief_lynn

    We doing online training so I'ma send this to our training sessions

  • @gort400
    @gort400 Před rokem

    Thank You!

  • @gort400
    @gort400 Před rokem

    Thanks

  • @gort400
    @gort400 Před rokem

    GREAT Video! It has helped my studies for AO Promotion. Thank You

  • @user-jq9yd6qo8s
    @user-jq9yd6qo8s Před 2 lety

    czcams.com/video/v0jBOINNeQA/video.html

  • @awpatt
    @awpatt Před 2 lety

    In order to "overdrive your siren" you would have to be travelling with a combined speed (meaning that the person's speed driving away from you would have to be added) of more than 767.269 MPH. Give or take based on humidity and other factors. But yeah. The speed of sound is much greater than that of a fire engine. People may not hear your siren because of a whole myriad of reasons, but "overdriving" it probably is not one of them.

  • @Keeping-it-real71
    @Keeping-it-real71 Před 2 lety

    Super job explaining! Made very simple. Thank you

  • @charronl.allensr4843
    @charronl.allensr4843 Před 2 lety

    Great video. This helps me a lot

  • @danielflores-xk2iy
    @danielflores-xk2iy Před 2 lety

    29.7 o 29.84 ???

  • @406fish1
    @406fish1 Před 2 lety

    keep in mind, they now require all personal to have helmets off inside a apparatus.

    • @mattp8050
      @mattp8050 Před rokem

      Came to the comments to say this! Having your helmet on while the vehicle is moving can break your neck if you have a hard stop.

  • @firstaidunit3391
    @firstaidunit3391 Před 2 lety

    What is an EVOC. Is it an online class or an offline class? How long is EVOC training? Do I need a driving license to learn this course? Will we have to drive a vehicle in this course?

    • @southchicagoheightsfiredep8511
      @southchicagoheightsfiredep8511 Před 2 lety

      EVOC stands for Emergency Vehicle Operator Course. Licensing requirements vary by state. Yes, you will have to drive an emergency vehicle to complete an EVOC course.

  • @4funtower401
    @4funtower401 Před 2 lety

    Very well explained & Super Amazing nd informative video. Thank you

  • @stephenjake2021
    @stephenjake2021 Před 3 lety

    Thank you for the help! Learning this in the academy right now

  • @owensweetland342
    @owensweetland342 Před 3 lety

    Great video.

  • @ryhawks49
    @ryhawks49 Před 3 lety

    Why is nozzle pressure no longer square rooted?

  • @stevenbowers4164
    @stevenbowers4164 Před 3 lety

    Why do US fire departments use tankers so much, would not a HVP save considerably in manpower requirements?

    • @awpatt
      @awpatt Před 2 lety

      If I understand HVP to mean High Volume Pump accurately, then the reason is that there is not a static water source to pump from, normally. Having a "tanker" (it is actually referred to as a Water Tender here in the Western US, as a Tanker means an aircraft filled with Retardant or Water) allows you to bring the water to the Emergency so as to supply the Engine Company on scene. You can either hook the Tender right up to the Engine, or you can dump in to static ponds. A High Volume Pump is equipped on some Tenders, and also, at least in the Departments that I volunteer for, we have old school Military Pumps that we can plumb into the lake. They are extreme, for sure. They are diesel powered and have four, 6" discharge ports. And yes, they are able to run them simultaneously. I hope that answered you question adequately. If I missed you meaning, please follow up! I love discussing Fire Department Tactics and Strategy!

  • @michaelngethe6381
    @michaelngethe6381 Před 4 lety

    Thanks for the lesson, some learning and safety tips grabbed.

  • @freedreaming2482
    @freedreaming2482 Před 4 lety

    So the number (29.7) where does that number or constant come from?

  • @lesterriquelme281
    @lesterriquelme281 Před 4 lety

    HOW TO CALCULATE THE REACTION FORCE IN FOG NOZZLES?

  • @r.hernzz
    @r.hernzz Před 5 lety

    Awesome videos. BIG HELP cause I was lost. Thank you sir.

  • @bonolib8979
    @bonolib8979 Před 5 lety

    Before you start...whens the baby due hehehehehe

  • @mohammednadeem649
    @mohammednadeem649 Před 5 lety

    How we get 9.48

  • @SledgeHammer43
    @SledgeHammer43 Před 6 lety

    The first department I has on we would set up a fill site with enough lines to fill up to 3 tankers at one time. A typical 1500 gpm pump may flow 2200 gpm from draft. Being from the Mabas Division 101. Back when we had a cork factory on fire we flowed sustained 6000 gpm. At times we were flowing 8000 gpm, the hard thing was refueling the Engines at the fill sites. Fill sites seem to always have tankers 2 and 3 deep refilling having one almost full one about 1/2 full and one backing in to fill. On a five alarm plus two interdivionals. We had equipment north to south from Milwaukee to Chicago. This took 4 fill sites one artesian well flowing 1000gpm 4 Fill sites on a lake each with a Engine Qmax Hale 1500 GPM pumps. And 2 Firefighters and a Engineer. As you are filling one at maximum gpm let the extra pump gpm fill a second tanker backing in a 3rd and connecting it up. Keeping one at the empty tanker and one at the nearly full. As the nearly full finishes filling. That firefighter shuts off the filling lines and then opens fully the 1/2 full tanker and half opens the valve to the empty tanker. Then both firefighters can release the full tankers lines and pull them back 10 to 15 feet. And then the process starts all over again. Of course all our tankers had a 3 inch and a 4 inch intake. Most had 3 way 10" dumps on the rear and were 3500 gallons. Also all our portable tanks were interconnected with the drain sleeves using Fol-da- Tanks drain sleeve connectors. Water supply needs its own channel, fill locations use a 5way manifold with only 2 2.5 gated outlets and 3 5" gated outlets. 50 ft 5" sections make this easier. Also having a rehab mobile pickup or van to bring support supplies such as Gatorade and food to fill sites helps keep things moving quickly. When running multiple fill sites it is needed to assign tankers to fill sites. These fill sites need to be fairly large and can be set up alongside a roadway, large boat launch, but not a dead end street only forcing tankers to back up short distance is the second best a truck length or 2. A straight pull up and drive out is best. Using a road way always keep one lane open. Marking the stopping points with reflective traffic cones. We couldn't have asked for a better time to have a ISO certification done that day.

  • @cbvpaz03
    @cbvpaz03 Před 6 lety

    where can I find the constant demonstration, which is used in this formula, 29.7 ???

  • @tonycook6817
    @tonycook6817 Před 7 lety

    What's the time limit?

  • @garthks
    @garthks Před 7 lety

    In order to place the Front Mount Pump in Pump Gear, there was a lever directly under the Intake of the Pump, with a Small Knob on the lever. Pull the Knob out toward you, and turn the Pump Gear Handle to the Opposite Side from it's original position, and release the Knob, this placed the Front Mount Pump into Pump Gear, with the Ability to Pump, and Roll.

  • @garthks
    @garthks Před 7 lety

    I remember an old 1956 Ford Brush Truck with a Front Mount Pump, and to place the front Mount Pump in Pump Gear, t

  • @joshua12084
    @joshua12084 Před 7 lety

    thank you for this. its a big help

    • @bcestraining
      @bcestraining Před 7 lety

      You are very welcome. Glad I could help.

  • @keepingupwithkels5439

    what does the 1.57 represent and if you are trying to figure this out for handlines, does the size hose matter?

  • @bipinyadav1981
    @bipinyadav1981 Před 8 lety

    nice things