![Sharath multiworks](/img/default-banner.jpg)
- 215
- 1 810 319
Sharath multiworks
India
Registrace 6. 05. 2020
Video
How to change Cooler pads // కూలర్ గడ్డి మారడం ఎలా.
zhlédnutí 138Před 2 měsíci
How to change Cooler pads // కూలర్ గడ్డి మారడం ఎలా.
Servicing of Air cooler & Changing of grass pads.
zhlédnutí 327Před 3 měsíci
కూలర్ గడ్డి ఎలా మర్చుకోవాలి
సెయిలింగ్ ఫ్యాన్ winding ప్రాబ్లెమ్. "0" ₹ repair ఎలా చేయాలి
zhlédnutí 596Před 4 měsíci
"0" ₹ repair ఎలా చేయాలి.
Wall pipe line work // Switch board & Wiring connection.
zhlédnutí 174Před 6 měsíci
క్లాస్ రూం లో ఎలక్ట్రిక్ పైప్ లైన్ వర్క్ // స్విచ్ బోర్డ్, ట్యూబ్, ఫ్యాన్ ఫిట్టింగ్ డీటైల్స్
Heat exhaust fan // Unboxing // Installation
zhlédnutí 274Před 6 měsíci
Full Unboxing & Installation of RS Heat exhaust fan
Orient wall mount fan // unboxing & review details.
zhlédnutí 420Před 7 měsíci
Full Installation details of orient wall mount fan. Product details : Orient Electric Wall-47 Trendz 400mm High Speed Wall Fan
Electrical house wiring // Fitting details Part-2
zhlédnutí 1,2KPřed 8 měsíci
Electrical house wiring // Fitting details Part-2
Electrical house wiring // Material details Part-1
zhlédnutí 358Před 8 měsíci
Electrical house wiring // Material details Part-1
How to change SYPHON set for western basin.
zhlédnutí 733Před 9 měsíci
How to change SYPHON set for western basin.
Angle cock water pressure // వాటర్ ప్రెజర్స్ తగ్గితే ఎమ్ చేయాలి.
zhlédnutí 207Před 9 měsíci
Angle cock water pressure // వాటర్ ప్రెజర్స్ తగ్గితే ఎమ్ చేయాలి.
Dewalt Grinding # Cutting # Machine Unboxing & Review in Telugu
zhlédnutí 217Před 9 měsíci
Dewalt Grinding # Cutting # Machine Unboxing & Review in Telugu
Water tank over flow Alarm // Unboxing video.
zhlédnutí 118Před 10 měsíci
Water tank over flow Alarm // Unboxing video.
Tap lekage // New tap fitting details // Telugu
zhlédnutí 298Před 10 měsíci
Tap lekage // New tap fitting details // Telugu
Digital Multimeter Unboxing & Review.
zhlédnutí 176Před 10 měsíci
Digital Multimeter Unboxing & Review.
Flush tank fitting details // ఫ్లష్ ట్యాంక్ ఫిట్టింగ్
zhlédnutí 202Před rokem
Flush tank fitting details // ఫ్లష్ ట్యాంక్ ఫిట్టింగ్
20amp socket // 10 amp switch burning issue // Solved
zhlédnutí 310Před rokem
20amp socket // 10 amp switch burning issue // Solved
Water 💦 is sprinkle from the Air Cooler
zhlédnutí 3,8KPřed rokem
Water 💦 is sprinkle from the Air Cooler
Cooler controlled by normal switches // mobile can be charged
zhlédnutí 509Před rokem
Cooler controlled by normal switches // mobile can be charged
Air Cooler Full switches connections // స్విచ్ వైరింగ్ కనెక్షన్స్
zhlédnutí 961Před rokem
Air Cooler Full switches connections // స్విచ్ వైరింగ్ కనెక్షన్స్
Series test lamp // 2 నిమిషాల్లో రెడీ చేసుకోవచ్చు
zhlédnutí 1,1KPřed rokem
Series test lamp // 2 నిమిషాల్లో రెడీ చేసుకోవచ్చు
Day - 3 # in Coorge // Madikeri // Abbi water falls
zhlédnutí 88Před rokem
Day - 3 # in Coorge // Madikeri // Abbi water falls
Sink లో వాటర్ పోవడం లేదు// డ్రైనేజ్ Blocked// ఏలా క్లియర్ చేసుకోవాలి.
zhlédnutí 555Před rokem
Sink లో వాటర్ పోవడం లేదు// డ్రైనేజ్ Blocked// ఏలా క్లియర్ చేసుకోవాలి.
సీలింగ్ ఫ్యాన్ కరెంట్ పైపుల్లో వాటర్ లీక్ అవుతున్నాయి
zhlédnutí 1,5KPřed rokem
సీలింగ్ ఫ్యాన్ కరెంట్ పైపుల్లో వాటర్ లీక్ అవుతున్నాయి
2-way tap to Angle cock // యాంగిల్ కాక్ హెల్త్ ఫాసెట్ ఫిట్ చేయడం ఎలా
zhlédnutí 259Před rokem
2-way tap to Angle cock // యాంగిల్ కాక్ హెల్త్ ఫాసెట్ ఫిట్ చేయడం ఎలా
Ceiling fan dimmer wiring // PART-2 // connection. స్విచ్ బోర్డులో రెగ్యులేటర్ కనెక్షన్ ఎలా ఇవ్వాలి.
zhlédnutí 258Před rokem
Ceiling fan dimmer wiring // PART-2 // connection. స్విచ్ బోర్డులో రెగ్యులేటర్ కనెక్షన్ ఎలా ఇవ్వాలి.
adhura knowledge dangerous he. 😂😂😂😂😂😂😂
Bro, what is this adapter called?
@@swarupsukai7162 Adaptor is an element which will help us to connect between the wires and bulb holder
👍
Boss harpic vesamu black ipoindi boss
@@rajendraprasadjillellaraje1350 ekkuva sepu vunchoddu bro.
Anna transformer to fuse bord (3 phase motor) RYB wire size and name cheppu anna
@@srisailamkongalla entha HP ki bro ?
Bro ma Surya pedastrail fan koni three months avtunde pedda ga sound oche fan uugipoye fan slow ai aagipotunde ente prblm bro
@@devikadasari8369May be bushes fail ipoyayi bro. Ante heat ki burn out ite vuntayi oksari check cheyandi.
Same coller gadiiki shock kodtudi
Problem solve kavtm ledu brother
@@kishorenaidugorle8112 meku exactly current shock ekkada vastundhi bro. Ante perticular ga Edina thing on chesinappudu.
Sympony coler ki main scad vesina ayina shock vastundi
@@kishorenaidugorle8112 check both wire bro.
S trap ante enti P trap ante enti A trap better bro
@@shivasand7557 52sec to 60sec video lo vati outlet chudu bro oksari.
@@shivasand7557 a trap better ani em leadu bro ma requirement taggatu ga tesukovadame nothing is best or waste.
Thanks tammudu
@@yeswanthbabud2622 you are most welcome brother.
Enka power tho Pani ledhu kadha
@@rangaRanga-h6v avunu andi.
సూపర్ తమ్ముడు
Thank you so much
Super anna ❤️ u
@@VickyVicky-ts8vx thank you so much😍 broo
Tqqq anaa
@@rudravenikarthik8027 you are welcome
Good explanation bro
@@santhoshkumar-hg5so thank you so much
Seling fan winding lo 1 peace cut ithey em cheyyali
@@durgaraoponduri2513 same elage cheyochu
TQ bro superb
Welcome
Brother if the pump is switched off, earthing occurs.. Spontaneously if i invertly insert the plug, shock is not there. Vice versa. Its confusing.
Earthing will flow unless or until the switch is Off, once power is supplied then phase will flow in that same path. Also, there are 2 wires one is commonly connected to all items the other one mutually connected through the switch. Here the logic is any one of the fire flows got damaged that's why when you invert the plug then the natural will get start flows in that damaged wire so that will cause any problem to us.
Thank u so much brother.. Last trick worked for me ( switching the plug )
You are most welcome bro
మంచిగా వివరించారు bro 🤝Tq
You are welcome
Ok bro tq
Cooler anni switch lu(swing,fan,pump) off chesinappudu shok vastundi anna Fan on cheste ravatledu malli
Ite main power supply wire problem vundochu bro.
@@sharathmultiworks5509 ela resolve cheyali bro
@@saikiranpinnam5133 wire change chesi chudandi.
@@sharathmultiworks5509 ok
Chinna pillalaku current current shok kodutundi cooler shok kuttindi 5years ammayi chanipoyindi
ekkada jarigindhi edi, very sad.
Sir మిరు ఎక్కడ ఉంటారు..hyd.. నా.. మి లాంటి good వర్కర్ హెల్ప్ మాకు కూడా కావాలి
Yes I am from Hyderabad. Contact me 9989650744
@@sharathmultiworks5509 uppal.. ఉప్పల్.. వస్తారా. మా రూం కి
Super
Thank you so much
Sases❤
Bushes రేట్ ఎంత బయట దొరుకుతుంద????
Ha బయట దోర్కుతుంది కానీ price idea లేదు.
Hi brother madhi LG 1.5 ton ac ki 20 amp MCB vundhi adhi trip avutundhi ani gold medal 25 amp mcb vesaru electrician appati nunchi trip avvadam ledu asalu 25 amp mcb veyacha and AC outdoor unit bodyki tester petti chuste lightga current vastundhi enduko cheppandi brother
Meru cheppina vidanga ite, problem MCB di kadu bro, earth problem vundhi adhuke MCB trip itundhi
1st meru aaa issue ni resolve chesukondi, 25amp veste trip avatleadu ante AC karab itadi.
@@sharathmultiworks5509 thanq so much brother replay ichhinanduku 😊
@@nagurowtula8364 you are welcome bro
Bro symphony cooler capacitor lo fire sparkles vastunnai fan on cheste .. What is the reason 🤔?
Cooler body lo current leak ayitundhi
May be due to loose contact.
@@srinathTingilkar-cm- check the phase wire joints
Tq annaa
Welcome anna
Super bro set aindi TQ
You are welcome bro
U must give earthing bro
Yes, we have suggested
How to fit stabilizer
Like Are you asking about installation or about connection.
Connection through MCB and stabilizer and a.c
@@ugendhardandagala4116 you don't wanna keep another MCB, almost in all stabilizer it self MCB connection will be their. If not 1st MCB next stabilizer next Ac.
While construction my home we already installed MCB connect,now I want installed a c with stabilizer, should I connect my stabilizer wire direct to mcb
@@ugendhardandagala4116 yeah sure
Thank you so much brother it's working 👍
You are welcome
Good explanation bro.
Thank you 🙂
Nice explanation
Thank you so much
@@sandeepragi8004 Am good 😊, contact me on this 9381380838.
Plug the girega Konda switched Agra connection macha👍
Thank you macha
ఆ switch కూడా ఎలా చేయాలో చూపిస్తే బాగుండు కదా అన్న.
తప్పకుండా అన్న, అలాంటి వీడియో కూడా చేస్తాను.
👍
Good 👍
Thank you
Cooler tirugutndi but room cool avatledu bro 2days nundi, side nundi door tisi water postam rju
Side pads lo dust vundhi emo bro, clean cheyandi
ఫ్యాన్ screw not loose
Can someone explain the summary in English?
Yeah I can explain to you bro. That's not a problem. You can tell me what is the issue you are facing.
@@sharathmultiworks5509 There was an issue reported by contract worker that while adjusting the fins of a plastic body water cooler, he felt electric shock and the ELCB connected with the cooler tripped at that instance as well. I want to know why did that happen?
@@MutahirRasool yeah sure, there might be earthing problem with that cooler check that.
Check the cooler wire damage as well.
Brother old fridge ki reley petti chusthe cool avvatle reley tesethe cool vadthundhi em cheyyali
Exlent bro 👍👍👍
Thank you bro
broooo motor sound vosthundi kani fan thirahadam ledu stuck ainatu vosthundi problem enti
Bushes patesi vuntayi.
Bro iron cooler fan on cheste vibration vastundi and off chesina tight ga tirugutundi condenser change chesi chusa
Condenser kadu bro, bush check cheyandi.
@@sharathmultiworks5509 ok bro
Good video, I changed the wire in the 3pin plug, interchange them leave the green earth. The problem is solved. Make your video in English and Hindi/Urdu too.
Thank you so much, yeah basically most of the count in the channel was Telugu so I was making it in Telugu, but if you have any doubt you can ask me with your comfort language I can give you the answer in your language that's not a problem.
Thank you so much
నేను ఎప్పుడో ఫిల్టర్ క్లీన్ చేసిన అయిన వాటర్ రావడం.లేదు..మాది 5th ఫ్లోర్
Okay tap entrance lo spindle degara kuda dust vuntundhi