VelanSteamTraps
VelanSteamTraps
  • 19
  • 117 660
VELAN MFT MOVIE
VELAN MFT MOVIE
zhlédnutí: 18

Video

Velan TS animation
zhlédnutí 27Před 3 měsíci
Velan TS animation
Eliminate Plugging
zhlédnutí 363Před 5 měsíci
Eliminate Plugging
Float Trap Steam Trap Animation
zhlédnutí 1,2KPřed 3 lety
Float Trap Steam Trap Animation
Inverted Bucket Steam Trap Animation
zhlédnutí 20KPřed 3 lety
Inverted Bucket Steam Trap Animation
Thermodynamic Steam Trap
zhlédnutí 76KPřed 3 lety
Thermodynamic Steam Trap
Thermodynamic Steam Trap Animation
zhlédnutí 16KPřed 3 lety
Thermodynamic Steam Trap Animation
Velan SPF Steam Trap Animation
zhlédnutí 403Před 3 lety
Velan SPF Steam Trap Animation
Velan Monovalve Float and Bimetallic Steam Trap (MFT) animation
zhlédnutí 552Před 3 lety
Velan Monovalve Float and Bimetallic Steam Trap (MFT) animation
Velan Universal Steam Trap (UST) Animation
zhlédnutí 332Před 3 lety
Velan Universal Steam Trap (UST) Animation
Velan Q250 Steam Trap Animation
zhlédnutí 136Před 3 lety
Velan Q250 Steam Trap Animation
Velan N150/300 Steamtrap Animation
zhlédnutí 292Před 3 lety
Velan N150/300 Steamtrap Animation
Velan SSF Steam Trap Animation
zhlédnutí 115Před 3 lety
Velan SSF Steam Trap Animation
Velan SF Steam Trap Animation
zhlédnutí 375Před 3 lety
Velan SF Steam Trap Animation
Velan TSF Animation
zhlédnutí 49Před 3 lety
Velan TSF Animation
History of Velan
zhlédnutí 381Před 3 lety
History of Velan
Velan LUNCH AND LEARN
zhlédnutí 101Před 7 lety
Velan LUNCH AND LEARN
Velan Steam Traps
zhlédnutí 1,3KPřed 7 lety
Velan Steam Traps

Komentáře

  • @dhruvrathod32
    @dhruvrathod32 Před 18 dny

    ghu

  • @iwgl1981JMR
    @iwgl1981JMR Před rokem

    Can these traps continually run if they have constant pressure on them?

  • @enhorgilbatbold8248
    @enhorgilbatbold8248 Před 2 lety

    how to make this video? i am trying to make working principle animation. which application was used for this video?

  • @tusharpatne6778
    @tusharpatne6778 Před 2 lety

    If steam loss is there, can we reutilise this steam from condensate discharge?

    • @nivruttiwandale6671
      @nivruttiwandale6671 Před rokem

      Yes they are having condensate lines from that we separate out the flash steam and hot condensate is sent to boiler feed water

  • @mostafakh1162
    @mostafakh1162 Před 3 lety

    👏🏻👏🏻😍👍🏻

  • @laithalshurafa5538
    @laithalshurafa5538 Před 3 lety

    Nice

  • @tamizhsadhasivam7153
    @tamizhsadhasivam7153 Před 3 lety

    Your contact pls

  • @AdrianButler86
    @AdrianButler86 Před 3 lety

    Please talk about how an inverted bucket trap is also good at using steam. If i understand it correctly the very design of the trap in order to function right must be made such that it remains primed at all times. Which means that the incoming steam bubbling up from the bottom of the water filled trap will more readily condense. This makes sense when u also realize that the trap is designed to not empty itself as much as possible. It needs some water in it to readily condense the incoming steam from the bottom. Its a perpetual self sustaining process. Am i wrong?

  • @Omkar_9100.
    @Omkar_9100. Před 3 lety

    Good

  • @SlipKnoT212552
    @SlipKnoT212552 Před 6 lety

    For the depiction of the saturated steam curve and segmented bimetallic element which closely follows it, it is suggested that for the steam shown in the test rig, at ~100 psig, only ~20°F of subcooling would open the trap. However, the trap clearly doesnt discharge until a much lower temperature in the experiment, one which seems consistent with a single bimetallic "conventional" element? How is this appropriate for saturated steam service? How long of a cooling leg is necessary?