![Caleffi Hydronic Solutions](/img/default-banner.jpg)
- 1 144
- 13 773 828
Caleffi Hydronic Solutions
Registrace 18. 11. 2011
Manufacturer of high-quality components for heating, plumbing, air conditioning and renewables systems, for domestic and industrial plants.
The company's guiding principle has not changed: to be aware of our own potential and our own values, while staying true to our roots and our identity. Just as it has been from the very beginning, constant attention is dedicated to quality (and its certification), technical product details (continuous improvements inspired by customer feedback) and innovation (with the due research periods necessary to avoid rushed development in pursuit of fleeting market trends).
More than 1.300 employees all over the world, 3 manufacturing premises all set in Italy, subsidiaries and offices all over the world. Two are the challenging projects we've been investing in for some years now: the CUBOROSSO (REDCUBE) Studies and Research Centre and the MAV Automatic Vertical Warehouse which guarantees even faster shipment and more punctual delivery.
EXPERIENCE US.
The company's guiding principle has not changed: to be aware of our own potential and our own values, while staying true to our roots and our identity. Just as it has been from the very beginning, constant attention is dedicated to quality (and its certification), technical product details (continuous improvements inspired by customer feedback) and innovation (with the due research periods necessary to avoid rushed development in pursuit of fleeting market trends).
More than 1.300 employees all over the world, 3 manufacturing premises all set in Italy, subsidiaries and offices all over the world. Two are the challenging projects we've been investing in for some years now: the CUBOROSSO (REDCUBE) Studies and Research Centre and the MAV Automatic Vertical Warehouse which guarantees even faster shipment and more punctual delivery.
EXPERIENCE US.
Small Scale Hydronic Cooling
Air-to-water and water-to-water heat pumps are often equipped with refrigerant reversing valves, allowing them to function as chillers. Small-scale chilled water cooling systems can be configured for various heating/cooling loads, client expectations, and budgets. When properly designed and installed, these systems provide several advantages over competing cooling methods. However, critical details must be accounted for in order to avoid problems and maintain system performance. John Siegenthaler, P.E., will cover all these topics and more in this 90-minute webinar.
Topics of discussion:
→ Is it necessary to insulate PEX piping when distributing chilled fluids?
→ Is there more than one way to zone chilled water cooling?
→ Can a heat pump provide both cooling and domestic hot water during the summer?
→ What approach can be used to provide multi-zone heating along with single-zone cooling?
Siegenthaler is a seasoned industry leader and passionate teacher, eager to share his over 40 years of experience in the understanding and proper application of water-based engineering principles with our audience. He is the principal of Appropriate Designs and a regular contributor to industry publications.
Topics of discussion:
→ Is it necessary to insulate PEX piping when distributing chilled fluids?
→ Is there more than one way to zone chilled water cooling?
→ Can a heat pump provide both cooling and domestic hot water during the summer?
→ What approach can be used to provide multi-zone heating along with single-zone cooling?
Siegenthaler is a seasoned industry leader and passionate teacher, eager to share his over 40 years of experience in the understanding and proper application of water-based engineering principles with our audience. He is the principal of Appropriate Designs and a regular contributor to industry publications.
zhlédnutí: 534
Video
Dentro il Cuborosso: la vostra Expertise | Devis Barcaro e Marco Godi ep.8
zhlédnutí 205Před 14 dny
Durante l'esposizione di MCE 2024 a FieraMilano, all'interno del Cuborosso, abbiamo ospitato alcuni installatori e progettisti per sentire le loro opinioni su Caleffi XF e sull'evoluzione del mondo HVAC. Insieme ai nostri tecnici, scopriamo come sta andando il mercato delle pompe di calore e i feedback sui nostri prodotti! Oggi un'ospite d'onore, amico e a sua volta creatore di contenuti: Devis...
Dentro il Cuborosso: la vostra Expertise | Davide Paci, Andrea Fabbri e Marco Godi ep.7
zhlédnutí 104Před 21 dnem
Durante l'esposizione di MCE 2024 a FieraMilano, all'interno del Cuborosso, abbiamo ospitato alcuni installatori e progettisti per sentire le loro opinioni su Caleffi XF e sull'evoluzione del mondo HVAC. Insieme ai nostri tecnici, scopriamo come sta andando il mercato delle pompe di calore e i feedback sui nostri prodotti! Un’interessante confronto da cui emergono anche consigli per le giovani ...
Termoregolazione e contabilizzazione attraverso l’utilizzo dei moduli d’utenza - Coffee with Caleffi
zhlédnutí 215Před 21 dnem
Termoregolazione e contabilizzazione attraverso l’utilizzo dei moduli d’utenza. ☕#CoffeewithCaleffi ☕ 𝐶𝑜𝑓𝑓𝑒𝑒 𝑤𝑖𝑡ℎ 𝐶𝑎𝑙𝑒𝑓𝑓 𝑒̀ 𝑢𝑛 𝑝𝑟𝑜𝑔𝑒𝑡𝑡𝑜 𝑑 𝑓𝑜𝑟𝑚𝑎𝑧𝑖𝑜𝑛𝑒 𝑡𝑒𝑐𝑛𝑖𝑐𝑎 𝑜𝑛𝑙𝑖𝑛𝑒 𝑔𝑟𝑎𝑡𝑢𝑖𝑡𝑎 𝑑𝑒𝑠𝑡𝑖𝑛𝑎𝑡𝑎 𝑎 𝑜𝑝𝑒𝑟𝑎𝑡𝑜𝑟 𝑑𝑒𝑙𝑙'𝑖𝑛𝑑𝑢𝑠𝑡𝑟𝑖𝑎 𝐻𝑉𝐴𝐶 𝐼𝑡𝑎𝑙𝑖𝑎𝑛𝑎, 𝑑𝑎𝑔𝑙 𝑖𝑛𝑠𝑡𝑎𝑙𝑙𝑎𝑡𝑜𝑟 𝑎 𝑝𝑟𝑜𝑔𝑒𝑡𝑡𝑖𝑠𝑡𝑖, 𝑎 𝑔𝑟𝑜𝑠𝑠𝑖𝑠𝑡 𝑑 𝑠𝑒𝑡𝑡𝑜𝑟𝑒. I moduli d'utenza assicurano l’autonomia termica delle unità abitative e la corretta valutazione dei consumi congiuntam...
Dentro il Cuborosso: la vostra Expertise | Davide Ferrari, Francesca Degasperis e Giacomo Ruga ep.6
zhlédnutí 104Před měsícem
Durante l'esposizione di MCE 2024 a FieraMilano, all'interno del Cuborosso, abbiamo ospitato alcuni installatori e progettisti per sentire le loro opinioni su Caleffi XF e sull'evoluzione del mondo HVAC. Insieme ai nostri tecnici, scopriamo come sta andando il mercato delle pompe di calore e i feedback sui nostri prodotti! Nel sesto episodio della nostra serie ci troviamo con Davide Ferrari e F...
Thermal Balancing for DHW Size, Select, Apply
zhlédnutí 581Před měsícem
The Ask Caleffi team is back to talk about the various applications for thermal balancing valves in domestic hot water (DHW) applications. Cody Mack and Kevin Freidt will discuss the options thermal balancing technology present to designers and installers. This discussion will cover the many ways to keep recirculation energy efficiency high and water waste low in a plumbing system. → What are t...
Dispositivos para balanceamento dos circuitos - Como dimensionar o AUTOFLOW®?
zhlédnutí 128Před měsícem
As instalações de climatização modernas devem garantir um conforto térmico elevado e um baixo consumo de energia. Para isso, devem alimentar-se os terminais das instalações com os caudais de projeto corretos e realizar, assim, circuitos hidráulicos equilibrados. Os dispositivos AUTOFLOW® (www.caleffi.com/pt-pt/estabilizador-automático-de-caudal-cartucho-autoflow®-em-polímero-de-alta-resistência...
Dentro il Cuborosso: la vostra Expertise | Nicola Casari e Marco Godi ep.5
zhlédnutí 118Před měsícem
Durante l'esposizione di MCE 2024 a FieraMilano, all'interno del Cuborosso, abbiamo ospitato alcuni installatori e progettisti per sentire le loro opinioni su Caleffi XF e sull'evoluzione del mondo HVAC. Insieme ai nostri tecnici, scopriamo come sta andando il mercato delle pompe di calore e i feedback sui nostri prodotti! Nel quinto episodio, insieme a Nicola Casari, scopriamo in quali install...
Antevisão das futuras soluções Caleffi para bombas de calor
zhlédnutí 135Před měsícem
Nesta edição especial de Coffee With Caleffi, Fernando Oliveira, responsável pelo nosso departamento técnico, apresenta em detalhe os produtos que permitem reduzir os custos de manutenção, aumentar a poupança energética e maximizar o funcionamento das instalações com bomba de calor, e faz uma antevisão das novas soluções que serão introduzidas no nosso catálogo geral de 2024. Produtos apresenta...
Der neue Hocheffizienz-Entlüfter für Wärmepumpenanlagen - CALEFFI HED®
zhlédnutí 97Před měsícem
Wir freuen uns, Ihnen den neuen Hochleistungs-Luftabscheider Caleffi HED® vorstellen zu können, der speziell für Wärmepumpenanlagen entwickelt wurde. Wenn es darum geht, Ihre Anlage effizient und mit voller Leistung zu betreiben, ist der Luftabscheider von entscheidender Wichtigkeit, und hier macht Caleffi HED® den Unterschied. Mit seiner hochmodernen Technologie und der Konstruktionsqualität, ...
Dentro il Cuborosso: la vostra Expertise | Marco Diani, Alessio Cioni e Franco Ruga ep.4
zhlédnutí 96Před měsícem
Durante l'esposizione di MCE 2024 a FieraMilano, all'interno del Cuborosso, abbiamo ospitato alcuni installatori e progettisti per sentire le loro opinioni su Caleffi XF e sull'evoluzione del mondo HVAC. Insieme ai nostri tecnici, scopriamo come sta andando il mercato delle pompe di calore e i feedback sui nostri prodotti! Nel quarto episodio vediamo insieme a Marco Diani, installatore, come si...
The new high efficiency deaerator - CALEFFI HED®
zhlédnutí 225Před měsícem
We are proud to present the new Caleffi HED®, a high efficiency deaerator designed specifically for heat pump systems. When it comes to keeping your system running efficiently and to the best of its ability, a deaerator is essential - and this is where Caleffi HED® really makes a difference. With its cutting-edge technology and the high-quality construction that sets our brand apart, Caleffi HE...
Il circuito di ricircolo negli impianti sanitari: gestione, consumi e costi - Coffee with Caleffi
zhlédnutí 429Před měsícem
Il circuito di ricircolo negli impianti sanitari: approcci di gestione, consumi e costi. ☕#CoffeewithCaleffi ☕ 𝐶𝑜𝑓𝑓𝑒𝑒 𝑤𝑖𝑡ℎ 𝐶𝑎𝑙𝑒𝑓𝑓 𝑒̀ 𝑢𝑛 𝑝𝑟𝑜𝑔𝑒𝑡𝑡𝑜 𝑑 𝑓𝑜𝑟𝑚𝑎𝑧𝑖𝑜𝑛𝑒 𝑡𝑒𝑐𝑛𝑖𝑐𝑎 𝑜𝑛𝑙𝑖𝑛𝑒 𝑔𝑟𝑎𝑡𝑢𝑖𝑡𝑎 𝑑𝑒𝑠𝑡𝑖𝑛𝑎𝑡𝑎 𝑎 𝑜𝑝𝑒𝑟𝑎𝑡𝑜𝑟 𝑑𝑒𝑙𝑙'𝑖𝑛𝑑𝑢𝑠𝑡𝑟𝑖𝑎 𝐻𝑉𝐴𝐶 𝐼𝑡𝑎𝑙𝑖𝑎𝑛𝑎, 𝑑𝑎𝑔𝑙 𝑖𝑛𝑠𝑡𝑎𝑙𝑙𝑎𝑡𝑜𝑟 𝑎 𝑝𝑟𝑜𝑔𝑒𝑡𝑡𝑖𝑠𝑡𝑖, 𝑎 𝑔𝑟𝑜𝑠𝑠𝑖𝑠𝑡 𝑑 𝑠𝑒𝑡𝑡𝑜𝑟𝑒. In questo nuovo appuntamento continueremo la nostra analisi dei circuiti di distribuzione dell'acqua calda e f...
The Evolution of Hydronic Balancing
zhlédnutí 1KPřed měsícem
There are many tools designers, installers and balancing contractors can use to properly balance a hydronic system. These include a range of balancing valves, instruments to read differential pressure and flow rate, and software that simulates flows in complex piping systems. The evolution of balancing valve technology in the last decade gives designers and installers many choices to best match...
Dentro il Cuborosso: la vostra Expertise | Paolo Malnati e Francesca Degasperis ep.3
zhlédnutí 98Před měsícem
Durante l'esposizione di MCE 2024 a FieraMilano, all'interno del Cuborosso, abbiamo ospitato alcuni installatori e progettisti per sentire le loro opinioni su Caleffi XF e sull'evoluzione del mondo HVAC. Insieme ai nostri tecnici, scopriamo come sta andando il mercato delle pompe di calore e i feedback sui nostri prodotti! Nel terzo episodio scopriamo insieme a Paolo Malnati come si trova con C...
Responsabilità ambientale e innovazione: i nostri prodotti a MCE 2024 - Coffee with Caleffi
zhlédnutí 137Před 2 měsíci
Responsabilità ambientale e innovazione: i nostri prodotti a MCE 2024 - Coffee with Caleffi
Dentro il Cuborosso: la vostra Expertise | Fabrizio Gontero, Marco Godi e Franco Ruga ep.2
zhlédnutí 113Před 2 měsíci
Dentro il Cuborosso: la vostra Expertise | Fabrizio Gontero, Marco Godi e Franco Ruga ep.2
Il nuovo disaeratore ad alta efficienza - CALEFFI HED®
zhlédnutí 261Před 2 měsíci
Il nuovo disaeratore ad alta efficienza - CALEFFI HED®
Dentro il Cuborosso: la vostra Expertise | Lino Baroni e Marco Godi ep.1
zhlédnutí 135Před 2 měsíci
Dentro il Cuborosso: la vostra Expertise | Lino Baroni e Marco Godi ep.1
Hidráulica 9 - Protección de la red hídrica, hasta el grifo | Webinar Coffee with Caleffi
zhlédnutí 157Před 2 měsíci
Hidráulica 9 - Protección de la red hídrica, hasta el grifo | Webinar Coffee with Caleffi
Caleffi a Mostra Convegno Expocomfort 2024 - Un’altra esperienza indimenticabile -
zhlédnutí 147Před 2 měsíci
Caleffi a Mostra Convegno Expocomfort 2024 - Un’altra esperienza indimenticabile -
Paired for Performance: Heat Emitters and Heat Pumps
zhlédnutí 1,1KPřed 2 měsíci
Paired for Performance: Heat Emitters and Heat Pumps
Strategie di bilanciamento a garanzia del corretto comfort termico - Coffee with Caleffi
zhlédnutí 600Před 3 měsíci
Strategie di bilanciamento a garanzia del corretto comfort termico - Coffee with Caleffi
The Caleffi Green - Semi-automatic self-cleaning magnetic filter Caleffi XF 577 series
zhlédnutí 326Před 4 měsíci
The Caleffi Green - Semi-automatic self-cleaning magnetic filter Caleffi XF 577 series
The Caleffi Green - iStop® antifreeze valve 108 series
zhlédnutí 253Před 4 měsíci
The Caleffi Green - iStop® antifreeze valve 108 series
Idraulica 65| I sistemi ibridi caldaia - pompa di calore aria acqua - Coffee with Caleffi
zhlédnutí 551Před 4 měsíci
Idraulica 65| I sistemi ibridi caldaia - pompa di calore aria acqua - Coffee with Caleffi
Eliminación de suciedad en instalaciones hidráulicas cerradas | Webinar Coffee with Caleffi
zhlédnutí 184Před 4 měsíci
Eliminación de suciedad en instalaciones hidráulicas cerradas | Webinar Coffee with Caleffi
Componentes para instalações com bomba de calor - Caleffi Hydronic Solutions
zhlédnutí 512Před 4 měsíci
Componentes para instalações com bomba de calor - Caleffi Hydronic Solutions
Thanks ! good useful content
Is the hygroscopic air vent food safe? Im in the early stages of building a portable drinking water storage tank that will need to be able to be vented but not let any water out regardless of the orientation of the tank.
I get to remove the screw and that but how to adjust it to its corresponding number setting please explain clearly
Bad explanation
Guess it gets dirty by the filters
If I put a spring loaded check valve in front of the preventer will that stop it from venting because of hammering?
Muy pocos videos muestran el funcionamiento de un venturi y sus partes por dentro muchísimas gracias
Made no sense at all flow/return temperature how to measure it.
Serve para calefação residencial? Para realizar a purga do ar em radiadores de alumínio. (Água com temperatura de até 80°C)
Salve, all'ingresso della rete idrica e' installato un addolcitore, e' necessario anche un filtro di polifosfati, grazie Nicola
Buongiorno, l’addolcitore riduce la durezza dell’acqua limitando la formazione di calcare, ma non è in grado di proteggere da fenomeni corrosivi o aggressivi, pertanto l’utilizzo di un prodotto non esclude l’altro
W jakiej pozycji powinien być zamontowany reduktor? Pionowej czy poziomej jesli zachowany jest kierunek przepływu wody a zbiornik wody jest zamocowany pionowo?
Regulator ciśnienia, zgodnie z instrukcją obsługi, może zostać zamontowany w dowolnej pozycji z wyjątkiem pozycji „do góry nogami”. W razie dodatkowych pytań zachęcamy do skorzystania z materiałów technicznych firmy Caleffi bądź o kontakt z działem technicznym Caleffi Poland.
Dziękuję
Esiste un kit di sale del vostro brand o posso prendere per la ricarica un qualsiasi tipo di sale polifosfato?
Buongiorno, per poter ricaricare il dosatore di polifosfati Caleffi XP occorre utilizzare l'apposita ricarica F0001503.
Finalmente un video chiaro e comprensibile.
Scusi la mia ignoranza ma un defangatore si può mettere sulla linea di entrata acqua in casa cosi da poter mandare nel circuito acqua pulita o va messo solo sotto le caldaie?
Buongiorno, il defangatore è un dispositivo utilizzato per la pulizia del circuito chiuso di climatizzazione e serve a raccogliere le impurità derivanti dall'utilizzo dell'impianto. Questo non esclude l'installazione di un filtro sulla linea di adduzione dall'acquedotto, utile a eliminare le impurità presenti nell'acqua di rete.
like atıtm dc geldim
Hey what means when I see on the display a logo of a clock? Pls help me
Bravo, spiegazione sintetica e chiara. Grazie
Boa tarde, por vezes com a 6000 bloqueia e não aumenta a temperatura
Czy odpowietrznik na sprzegle ma byc caly czas otwarty? Tak jak w filmie?
Dzień dobry, dla poprawnego i sprawnego usuwania powietrza z instalacji zawór odpowietrzający powinien być cały czas otwarty. Zawór upuszcza powietrze w momencie gdy zbierze się go określona ilość w korpusie powodując podniesienie się pływaka i upust. W razie dodatkowych pytań zachęcamy do kontaktu z działem technicznym naszej firmy: www.caleffi.com/pl-pl/kontakt/skontaktuj-sie-z-nami
This is the only video so far in entire CZcams which explains what a hobby house owner should do
What is the part number of the check valve at 10:08? I think our commercial 4 story building is having this problem. Would it cause other issues to install these check valves on the top floor of every unit if we are having a negative pressure issue? Top floor of the building is not heating during cold snaps. Air gets into system but then the system works as normal once the cold snap is over.
Salve ottimo webinar, avrei una domanda. Come faccio a sapere la portata massima di un canale (nell'esempio avete detto che per un canale 75DN è 30 m^3/h). Se avessi un diamentro del tubo maggiore come faccio a sapere la porta massima del canale? Grazie in anticipo
Buongiorno, la portata massima del tubo si ricava fissando una soglia massima alla velocità del flusso d'aria nel tubo. Nel dimensionamento si deve verificare che la velocità massima non superi i 3 m/s. Si avranno quindi come portate massime, 30 m3/h per il tubo DN75 e 50 m3/h per il tubo DN90.
Oltre ad avere il circolatore spento non bisogna scaricare la pressione dall'impianto (prima di intercettare la valvola)? Se il circuito é ad 1 bar relativo quando si apre il bicchiere verrà comunque spruzzata (la poca) acqua che c'è dentro con il rischio di sporcare tutto
Buongiorno, la pressione residua all'interno del bicchiere del filtro defangatore XS serve anche a favorire lo smontaggio. Una volta chiusa la valvola a sfera e intercettato il dispositivo non c'è alcun rischio che l'acqua spruzzi. Ovviamente occorre avere l'accortezza di tenere un canovaccio a portata di mano per assorbire le poche gocce d'acqua che fuoriusciranno per gravità.
Buongiono, volendo redigere un computo come mostrato con tutti i prodotti caleffi come consigliate o sarebbe opportuno procedere: 1) Redigendo il computo con le voci che si trovano sulle schede caleffi e poi utilizzare il prezziario (dei o altri) esclusivamente come comparazione per congruità dei costi (esempio indicando la voce a cui si fa riferimento); 2) Redigere il computo con le voci presenti nel prezziario (o in analisi prezzi se non presenti) e poi indicare da qualche parte a quali prodotti caleffi sono riferiti 3) Altro? Saluti
Buongiorno, nei capitolati per opere pubbliche non è possibile indicare un componente o un produttore specifico, ma bisogna utilizzare o le voci presenti nei vari prezziari o sfruttare quelle dei produttori, avendo però cura di renderle generiche (senza nome e cognome, per intenderci). Occorre sempre tenere presente che non tutti i componenti sono presenti nel prezziario.
Buongiorno, nel mio impianto a 4 zone con 4 pompe, l'idraulico ha montato il separatore Caleffi con i collegamenti lato caldaia invertiti (mandata dalla caldaia collegato sulla entrata in basso nel separatore e ritorno alla caldaia in alto) poiché tarda a correggere l'errore vorrei sapere che rischi corro a tenere l'impianto in funzione? Grazie
Buongiorno, non ci sono particolari rischi impiantistici che possano portare ad un danneggiamento dei componenti. L'unica problematica che si può ritrovare è una stratificazione all'interno del separatore idraulico che comporta una temperatura di mandata lato secondario leggermente inferiore nella fase di avvio e una messa a regime più lenta.
sono rumorose...le voglio togliere
Buongiorno, ci dispiace per l'inconveniente, ma la rumorosità, nella quasi totalità dei casi, non deriva dalla valvola termostatica, bensì da imprecisioni impiantistiche presenti magari da anni e mai riscontrate. Già dal tipo di rumore è possibile capire quale sia la tipologia di problema e risolverlo in modo semplice ed efficace.
Zdravo da li ovo moze podno grijanje na kotao kruta goriva
Took mine apart and tried to blow into it and flush it with water with the valve open. Still dripping. Any ideas?
i turbulence an issue in dropping water temps with recirculation pumps
De ce in romania este dezavantajata teava Pe-rt?
Im going to share this with the salesman at our company.....here in TX boiler knowledge is lacking. I was just at a job....new Viessman and a old Bryan water tube were there.....they installed a new air separator and didn't add an expansion tank and chopped off the piping to the existing compression tank....i was like WTF is going on here. Im not boiler Jesus by any stretch of the imagination....but dang this is boiler 101 stuff. Thanks for the video
Elinize sağlık helal olsun çok güzel anlatılmış
Posiadam taki regulator ciśnienia i przyszedł czas na wymianę wkładu (sitka stalowego) i mam pytanie czy jak ustawię regulator na 0 to odkręcając szkiełko z sitkiem woda poleci w miejscu gdzie jest ten wymienny wkład czy mogę spokojnie ustawić na 0 i wykręcić filtr pytam ponieważ mam zawór kulowy tylko z lewej strony
Do prac serwisowych wymagane są zawory odcinające przed i za urządzeniem. Nie jest możliwe odcięcie przepływu za pomocą samego urządzenia. W razie dodatkowych pytań zachęcamy do kontaktu z działem technicznym naszej firmy.
musisz zrobic , gdzies naczynie z poduszka powietrza , np , jak pionowa rure w ktorej bedzie troche powietrza [poduszka]
Same issue, I cannot adjust the valve
I have one that won't turn. I cannot change the temp of the water. The water comes in like warm at best. Help! I have tried lubricant and still won't turn. I took the call off and tried turning it with a vise grip and still won't turn.
Très agréable
GG
Transcrire en francais
Buonasera dai link e i commenti deduco che il tecnico (inviato da un noto negozio) che mi ha montato la caldaia e i termosifoni con questo tipo di valvole non ci capisce molto (per essere gentile). Ho un impianto monotubo e le valvole 455 comprese di valvole termostatiche mi sono state montate in questo modo: il detentore (mi sembra si chiami così) che si muove con la brugola da 10 è posizionato tutto in fuori (verso il tappino bianco) mentre quello che si muove con la brucola da 5 è tutto dentro. Da quanto studiato questa posizione non è corretta. Le valvole termostatiche le devo tenere al massimo perché se le imposto a 2, per esempio, il termosifone emette forte rumori o fischia al raggiungimento della temperatura. La mia affermazione è giusta, l'installazione non è stata fatta bene? Tuttavia dal video sembra che la valvola per trasformarla in bitubo il sistema governato dalla brugola da 10 deve essere spinto in dentro, distante dal tappino bianco, quindi, se fosse così, a casa mia sono settati bene. Per favore, voi che conoscete benissimo questo meccanismo scioglietemi questi dubbi, perché mi sembra ci sia una incongruenza tra il video e quello che ho letto dal sito delle valvole in questione.
Buongiorno, la configurazione monotubo della valvola in oggetto prevede che la brugola da 10mm sia completamente avvitata verso l'interno, mentre quella da 5mm deve essere lasciata completamente svitata
Molto gentile per la risposta. Mi avete chiarito una questione che avevo già capito dalla consultazione della scheda tecnica. Vorrei permettermi di dare un suggerimento dovuto alla mia personale esperienza: fate dei brevi corsi agli installatori e ai rivenditori. Nella realtà dovrebbero leggere le schede tecniche, ma nessuno lo fa. Basta che il termosifone si scalda che per loro va bene. Molti idraulici, tecnici e rivenditori da me contattati erano allo scuro della giusta configurazione per l'impianto mono tubo. Ancora non ho fatto le modifiche da voi consigliate al mio impianto, che funziona con la attuale configurazione sbagliata e con le valvole termostatiche al massimo, perché se raggiungono la temperatura impostata il termosifone fa un rumore fastidioso e l'impianto non funziona bene. Grazie ancora e spero che questo post serva di lezione ai tecnici installatori.
@@CaleffiHydronicSolutions buonasera ho bisogno di risolvere un dubbio in modo urgente. Ho una casa di 95 mq circa con impianto monotubo e molto fredda. Alcuni mi dicono che non centra la potenza della caldaia e alcuni invece che il problema potrebbero essere le valvole a muro dei caloriferi monotubo con caloriferi in ghisa. Avendo molti anni e quindi mai cambiate. Potrebbe aiutarmi con un consiglio come risolvere il problema del freddo? Le do qualche dato in piú. I caloriferi sono 6 di cui totale 52 elementi in ghisa. Appartamento dell'80 al primo piano con box sotto ed esposta al Nord, la temperatura non supera i 16 gradi. Al momento abbiamo una caldaia abbastanza datata con 24 kw. Pensavamo a una condensazione di 28 kw ma molti mi hanno detto che per il freddo il problema non é quello. Per cui, cosa possiamo fare? . Ci da un consiglio? Grazie.
@@talital1268 Buongiorno, gli impianti monotubo sono normalmente molto delicati da gestire in termini di potenza emessa. Per capire dove sia il problema del non riscaldamento della sua abitazione occorre valutare innanzitutto se la potenza termica dei radiatori installati sia sufficiente a coprire le dispersioni dell'edificio. Una volta fatto ciò, bisogna valutare che la temperatura di mandata e la portata del generatore siano adatte all'impianto installato. Tutto questo deve essere valutato da un termotecnico in seguito ad una analisi dell'impianto.
@@CaleffiHydronicSolutions grazie mille per i consigli. Per potenza radiatori intende il numero degli elementi dei caloriferi o la potenza che arriva dalla caldaia?
Microblasenabscheid3r muss noch extra oder?
Bonjour Est-ce que on peut le monter sur une installation avec une pompe à chaleur Mitsubishi. Merci
Bonjour, pour l'installation en combinaison avec les PAC, nous avons développé des séries spécifiques: la série 6445 (www.caleffi.com/fr-fr/vanne-%C3%A0-sph%C3%A8re-motoris%C3%A9e-trois-voies-6445-caleffi-644562) et la série 6383 (www.caleffi.com/fr-fr/vanne-%C3%A0-sph%C3%A8re-motoris%C3%A9e-trois-voies-avec-coque-disolation-pour-installations-de-chauffage-et-rafra%C3%AEchissement-638-caleffi-638373).
Quindi: per fare lavorare la valvola in mono tubo, bisogna aprire con la chiave da 10 in senso orario cioè nel senso in cui la valvola si avvita al bocchettone! Per il bilanciamento se si vuole tenere la valvola completamente aperta bisogna con la chiave numero cinque girare fino a battuta in senso orario alla valvola quindi cioè nel senso in cui la valvola si avvita al bocchettone (non nel senso in cui il bocchettone si avvita alla valvola come nel video) insomma: sia per avere la valvola mono tubosia per avere il bilanciamento tutto aperto a favore della stessa valvola bisogna girare sempre in senso orario
14:52 per centrali termiche di un mini condominio dove conviene installare il serbatoio di ACS?
Mi scusi, ma nel modo bitubo e' lo stesso dove viene presa l'entrata e uscita? O bisogna che sia l'entrata sulla pressa piu vicina al radiatore? Grazie 1000 e saluti dalla Croazia, Saša
Ho acqustato la testa termostatica, ma l'adattatore non capisco dove posizionarlo, sulle mie valvole caleffi vi è prensente una parte filettata che si accoppia perfettamente alla testa.
Buongiorno, l'adattatore filettato è da utilizzare per l'installazione del comando termostatico sulle valvole del tipo termostatizzabile. Se la valvola invece è già del tipo termostatico, si procede con l'installazione direttamente sulla filettatura già presente sul corpo.
What size is this mixing valve 3/4? Does anyone make a device like this that doesn't mix or change the water temp? I would love to bypass my mixing valve completely in my new home. Makes no sense, I can scald every faucet in the house including my kids tubs and showers but for the Master Bathroom Soaking Tub only where the adults bathe I can not get it past luke warm! Shower will burn you but soaking sux. I have a zurn mixing valve I even took it off, turned it around Hot to COLD cold to hot and it still only puts out cold water?
😮😮😮
ce l'ho su tutti i termosifoni di casa: peggior metodo per sostituire le batterie non poteva essere trovato. A parte i possesso delle penne Bic, che si spezzano, li dove dite premere non ha elasticità per cui non si preme una cippa. in questi giorni sto impazzendo per cambiiare le batterie esurite del salone, niente da fare non si stacca.
Buongiorno, effettivamente il tasto di sblocco del guscio su questa serie di comandi era leggermente difficoltoso da manipolare. La ringraziamo per la segnalazione.
What if the threads coming out of your buderus panel is male threaded? Is there an adapter to allow the caleffi valve?
Nessuno sa come si calcolano i consumi?