John Ward
John Ward
  • 533
  • 35 681 965
Diverted Neutral Current Demonstration - Normal, Open CNE, Current Circulation (Part 2)
A demonstration of diverted neutral current using a 12V AC test rig. This represents two adjacent properties with TN-C-S supplies via a CNE (combined neutral and earth) cable and a shared extraneous conductive part.
Demonstration includes:
► normal operation
► current sharing between the CNE and bonding conductors
► what happens with an open CNE in one property and not in the adjacent one
► the situation with more than two properties all connected to the same extraneous part.
In all cases, current can be found in the bonding conductors connected to shared metallic parts such as gas or water pipes.
Note that this demonstration uses a custom manufactured test rig which runs on an isolated 12 volt AC supply. Some of the items shown would be dangerous if done with 230V or a real electrical installation.
zhlédnutí: 68 263

Video

Diverted Neutral Current - Description Overview Part 1
zhlédnutí 26KPřed 9 měsíci
Diverted Neutral Current, also known as Neutral Current Diversion. This can occur both in normal operation and when there is a problem with the supply network. Part 1 covers the basic principles of both.
Extension Lead Repair - MK Panel Sockets
zhlédnutí 11KPřed 10 měsíci
Replacing panel mounted MK sockets in a metal extension reel. Sockets are MK 735WHI, and are the same size as those made decades ago. There is an ancient data sheet for the original ones here: docs.rs-online.com/739a/0900766b811ef79c.pdf which is dated July 1959. Flex is 2.5mm² 3 core PVC. This is significantly larger than most extension reels available today which are typically 1.5mm² or even ...
Wylex Mini Consumer Unit, RCBO and SPD
zhlédnutí 19KPřed 10 měsíci
A Wylex metal 2 way consumer unit, 40A Type A RCBO with switched neutral, and a Type 2 surge protection device. This one will be used for an EVSE installation, but it could be used for other situations where a new circuit is required. Box with main switch: NM206/63 Surge protection device: NMT2SPD3W/1 40A compact RCBO with switched neutral: NHXS1B40 Patreon: www.patreon.com/jwflame Ko-Fi: ko-fi...
Electric Vehicle Charging - Connectors, AC / DC, Home or Away
zhlédnutí 20KPřed 10 měsíci
Charging electric vehicles using AC or DC, and the Type 2 connector which is found on most recent electric vehicles in the UK and most of the world. Also covers older vehicles with Type 1 and CHAdeMO connectors, and the situation with Tesla vehicles and charging. Most of this does not apply to the USA, where Type 1 and Type 1 CCS is common for existing non-Tesla vehicles and Tesla has it's own ...
Power and Energy Monitor Plug
zhlédnutí 10KPřed 11 měsíci
A typical power and energy monitor that can be used with any plug in appliance. The main features are kWh and elapsed time. Also shows voltage, current, watts, VA and power factor. Patreon: www.patreon.com/jwflame Ko-Fi: ko-fi.com/jwflame Website: flameport.com/
Power and Energy - Watts vs Watt Hours, Energy Cost and Battery Capacity
zhlédnutí 21KPřed rokem
Watts vs Watt Hours Amp Hours to Watt Hours Power is the rate at which electricity is used, energy is the total amount used over a certain period of time. Includes example calculations for the total energy and cost used, and the capacity of batteries.
Types Of RCD
zhlédnutí 58KPřed rokem
Types of Residual Current Devices, Type AC, A, F, B and B . What each type is intended for and what fault currents they will work with. Effective September 2022, BS7671 requires a minimum of Type A for the majority of installations. However some devices are not suitable for use with Type A and require others such as Type F or B.
BS7671 18th Edition Amendment 2 Appendices
zhlédnutí 8KPřed 2 lety
BS7671 18th Amendment 2, published March 2022. The final episode in this series covers the changes in the 18th edition Amendment 2 appendices. IET Fake Awareness with list of approved suppliers: electrical.theiet.org/bs-7671/fake-awareness/ Other videos in this series: czcams.com/play/PLVsHvs2SuqmqMoXZCFp_CYTgZH_Y2ywwk.html ► Support this channel: Patreon: www.patreon.com/jwflame PayPal Donatio...
BS7671 18th Edition Amendment 2 Part 8
zhlédnutí 8KPřed 2 lety
BS7671 18th Amendment 2, published March 2022. This is a summary of the main concepts in the new Part 8, Prosumers Electrical Installations. IET Fake Awareness with list of approved suppliers: electrical.theiet.org/bs-7671/fake-awareness/ Other videos in this series: czcams.com/play/PLVsHvs2SuqmqMoXZCFp_CYTgZH_Y2ywwk.html ► Support this channel: Patreon: www.patreon.com/jwflame PayPal Donations...
BS7671 18th Edition Amendment 2 Part 7
zhlédnutí 6KPřed 2 lety
BS7671 18th Amendment 2, published March 2022. This covers some of the changes in part 7. IET Fake Awareness with list of approved suppliers: electrical.theiet.org/bs-7671/fake-awareness/ Other videos in this series: czcams.com/play/PLVsHvs2SuqmqMoXZCFp_CYTgZH_Y2ywwk.html ► Support this channel: Patreon: www.patreon.com/jwflame PayPal Donations: xo4.uk/?PPP ► Social Media: Twitter: ...
BS7671 18th Edition Amendment 2 Part 6
zhlédnutí 6KPřed 2 lety
BS7671 18th Amendment 2, published March 2022. This covers the main changes in part 6. Model forms download: electrical.theiet.org/bs-7671/model-forms/ IET Fake Awareness with list of approved suppliers: electrical.theiet.org/bs-7671/fake-awareness/ Other videos in this series: czcams.com/play/PLVsHvs2SuqmqMoXZCFp_CYTgZH_Y2ywwk.html ► Support this channel: Patreon: www.patreon.com/jwflame PayPa...
BS7671 18th Edition Amendment 2 Part 5
zhlédnutí 8KPřed 2 lety
BS7671 18th Amendment 2, published March 2022. This covers the main changes in part 5. IET Fake Awareness with list of approved suppliers: electrical.theiet.org/bs-7671/fake-awareness/ Other videos in this series: czcams.com/play/PLVsHvs2SuqmqMoXZCFp_CYTgZH_Y2ywwk.html ► Support this channel: Patreon: www.patreon.com/jwflame PayPal Donations: xo4.uk/?PPP ► Social Media: Twitter: jwf...
BS7671 18th Edition Amendment 2 Part 4
zhlédnutí 11KPřed 2 lety
BS7671 18th Amendment 2, published March 2022. This covers the main changes in part 4. IET Fake Awareness with list of approved suppliers: electrical.theiet.org/bs-7671/fake-awareness/ Other videos in this series: czcams.com/play/PLVsHvs2SuqmqMoXZCFp_CYTgZH_Y2ywwk.html ► Support this channel: Patreon: www.patreon.com/jwflame PayPal Donations: xo4.uk/?PPP ► Social Media: Twitter: jwf...
BS7671 18th Edition Amendment 2 Parts 1-3
zhlédnutí 27KPřed 2 lety
BS7671 18th Amendment 2, published March 2022. This covers the main changes in part 1, 2 and 3. Electropedia website: www.electropedia.org/ IET Fake Awareness with list of approved suppliers: electrical.theiet.org/bs-7671/fake-awareness/ Other videos in this series: czcams.com/play/PLVsHvs2SuqmqMoXZCFp_CYTgZH_Y2ywwk.html ► Support this channel: Patreon: www.patreon.com/jwflame PayPal Donations:...
Driving Electric Vehicles - Not much different to any other car or van
zhlédnutí 17KPřed 2 lety
Driving Electric Vehicles - Not much different to any other car or van
TT Installations
zhlédnutí 56KPřed 2 lety
TT Installations
Racal-Guardall 1980s PIR Sensor Teardown - Compared with Modern Equivalent
zhlédnutí 11KPřed 2 lety
Racal-Guardall 1980s PIR Sensor Teardown - Compared with Modern Equivalent
ConduDisc Final Tests - 4 Months Later
zhlédnutí 17KPřed 2 lety
ConduDisc Final Tests - 4 Months Later
Smoke Alarm Wiring Fail
zhlédnutí 49KPřed 2 lety
Smoke Alarm Wiring Fail
SY Cable is Not Armoured, Not for Outside Use
zhlédnutí 40KPřed 2 lety
SY Cable is Not Armoured, Not for Outside Use
Siemens VOELCB examination and Tinned Copper or Aluminium wiring?
zhlédnutí 12KPřed 2 lety
Siemens VOELCB examination and Tinned Copper or Aluminium wiring?
Octopus Box by Hartley Electromotives Limited 1958
zhlédnutí 25KPřed 2 lety
Octopus Box by Hartley Electromotives Limited 1958
Screws - Phillips or Pozidriv ?
zhlédnutí 127KPřed 3 lety
Screws - Phillips or Pozidriv ?
Led Tape Part 2
zhlédnutí 12KPřed 3 lety
Led Tape Part 2
Circuit Breakers Prague 1983
zhlédnutí 12KPřed 3 lety
Circuit Breakers Prague 1983
LED Tape Part 1
zhlédnutí 19KPřed 3 lety
LED Tape Part 1
ConduDisc and Conducrete Installation
zhlédnutí 17KPřed 3 lety
ConduDisc and Conducrete Installation
Pepperpot Fuses, Switch and Meter Card
zhlédnutí 12KPřed 3 lety
Pepperpot Fuses, Switch and Meter Card
Federal Electric Circuit Breakers
zhlédnutí 11KPřed 3 lety
Federal Electric Circuit Breakers

Komentáře

  • @andrewforsyth4799
    @andrewforsyth4799 Před 21 hodinou

    Think i got it second time round was looking at ring ,,thanks

  • @andrewforsyth4799
    @andrewforsyth4799 Před 21 hodinou

    Hi j, really like your channel its very informative, just come across this older vidio of yours which i do remember, could you explain how the newer iet brown book now reference's this same model regarding the 3036 fuse . They've changed the book because of your teaching ,,brill!!

  • @MeGrahamPage
    @MeGrahamPage Před dnem

    If you are in a shower area my existing pull cord switches a fan, Light and shower pump from the same switch. Is a special load carry switch necessary if you fitted juts outside shower room door? Will they carry the load? Should a relay be employed though; it still has to take a load ...so i am confused? yes your videos are a carming releaf from a importand but dry subject...thanks.

  • @gerryboy458
    @gerryboy458 Před 2 dny

    Very good way of explaining this.

  • @SPDTDL
    @SPDTDL Před 3 dny

    Afternoon JW. Just purchased a 4 year old new build. It has an EV charger installed using 2.5mm T&A, with a 25A MCB on the consumer unit. Charger has been capped to 25A using dip switches inside the unit. When I plug my car in, as expected it’s capped at 25A which is fast enough for me. Is this OK or should I be expecting a house fire? 😅

    • @jwflame
      @jwflame Před 2 dny

      May be acceptable, if the cable is either surface clipped or direct in the plaster/masonry. Not acceptable if it's in any kind of conduit or ducting, or passes through insulation. Even if it is surface clipped, it will get fairly warm in use, as it will be used pretty much at it's maximum rating.

    • @SPDTDL
      @SPDTDL Před dnem

      @@jwflame Thank you JW. I managed to find out it’s 'clipped direct'. However, below the consumer unit is a switch that enables me to turn the EV charger on and off. 20A Double Pole switch. I assume this would not be a good thing having 25A passed through it?

  • @ndear2955
    @ndear2955 Před 3 dny

    Wow what a stupid design, thanks for sharing!

  • @Webbster77
    @Webbster77 Před 4 dny

    John, so if I have a steel frame pergola in a garden that has lights and heaters attached and wired through the frame it would need bonding accordingly as well then?

  • @mickeyfletcher9292
    @mickeyfletcher9292 Před 4 dny

    Can you fit a rcbo in a panel protected by a RCD?

    • @jwflame
      @jwflame Před 3 dny

      Only if the RCBO can be connected directly to the main switch, and not via the RCD.

  • @majorredbeard
    @majorredbeard Před 4 dny

    Excellent description and thanks for the practical way of telling between them.

  • @chrisrhodes1127
    @chrisrhodes1127 Před 5 dny

    Diversity Perfectly explained !

  • @jakobrebeki
    @jakobrebeki Před 5 dny

    Dear John, have you quit doing CZcams videos....

    • @jwflame
      @jwflame Před 4 dny

      No, there will be more at some point.

  • @marklittler784
    @marklittler784 Před 5 dny

    Like going back to school 😊

  • @geniusmarcsays2434
    @geniusmarcsays2434 Před 6 dny

    he did not explain how he connected the wires...i mean what i see is a plug with the 2 wires touching, that's a short circuit

    • @jwflame
      @jwflame Před 3 dny

      It's a demonstration of the AFDDs. The wiring is not relevant, and isn't what would normally be used because it's just a demonstration.

    • @geniusmarcsays2434
      @geniusmarcsays2434 Před 3 dny

      @@jwflame yes, but i still want to know how you tripped the circuit.. did you make arc flash on a parallelle circuit?

  • @craiginboro679
    @craiginboro679 Před 7 dny

    The lighting circuit isn't RADIAL, they used to be. The lighting circuit is a Ring, you actually drew a ring circuit, ie the main conductor left the consumer unit and returned to it. A radial is where power is supplied to each device and doesn't have a return. Ps blue=black, brown=red. Unfortunately electricians use a red switch wire to connect to live. If they used a black switch wire to connect to the 'ring' live it would be obvious it was a switch wire. No extra bits of sheathing required.

    • @jwflame
      @jwflame Před 3 dny

      No idea which video you watched, but it certainly wasn't this one.

  • @georgedavall9449
    @georgedavall9449 Před 8 dny

    J.W. !!!!!!!!!!!!!!!!! Crackin video mate, but slow down and enunciate a little clearer, Sir, Thank You 🙄

  • @tobybutler9493
    @tobybutler9493 Před 8 dny

    Great video - clear and useful. Thx

  • @fredbettesworth5397
    @fredbettesworth5397 Před 10 dny

    ill have crabbtree dist boargs on site. Looking for blanking plates

  • @aminabbasipiani9131
    @aminabbasipiani9131 Před 11 dny

    hi guys, i have a question. how does SPD protect your electrical appliances? when a high voltage occurs and SPD detects it, will your circuits be isolated?

    • @jwflame
      @jwflame Před 3 dny

      The SPD becomes a short circuit for the duration of the overvoltage, so the voltage is reduced and the energy ends up as heat in the SPD. Nothing is isolated.

  • @ifell3
    @ifell3 Před 11 dny

    Hi John, looking at your inverter it has a grounding stud, is this a ground for the DC then? Kind regards

  • @alasdairmunro1953
    @alasdairmunro1953 Před 11 dny

    Pulled a few of those in my time as a firefighter, to isolate supply when BA crews are searching in a building.

  • @matthewhammond859
    @matthewhammond859 Před 11 dny

    Are the building regs statutory or not?

  • @jorgecastro199
    @jorgecastro199 Před 11 dny

    Hi, good job, can you tell me were i can get new brushes? Thank you.

  • @ross9580
    @ross9580 Před 11 dny

    Is the Americium a solid or an encapsulated powder? Any risk of a powerful compressed airblast accidentally dispersing it?

  • @digitraxuk
    @digitraxuk Před 12 dny

    Thank you John for another very clearly presented topic. With a TT system in the main house would it only be beneficial to connect the 10mm 3core SWA cable (cpc) to the outbuilding (with water and gas services) consumer unit MET where it has its own separate earth rod. I would imagine this setup, rather than keeping the two completely separate as you presented, is beneficial in trying to keep the Ra to a minimum. Or is it a pointlessly small benefit since you are relying on RCD for earth fault protection? I hope that makes sense? Many thanks for my crazy brain working overtime.

  • @scampbell8136
    @scampbell8136 Před 13 dny

    all my questions answered in ne video, great thank you .

  • @Rineality
    @Rineality Před 14 dny

    Don't be afraid john

  • @afzaalawan
    @afzaalawan Před 14 dny

    extreemly long video for a simple concept

  • @elmarbayramov9312
    @elmarbayramov9312 Před 14 dny

    What is the significance of the different colors of the clades?

  • @eazyrat
    @eazyrat Před 14 dny

    Thanks. I tried these tests got 50 ohms on one reading. The problem for me wasn't that the heater wasn't working but the reset kept activating. The water did seem very hot. Broken stat?

  • @GrahamBurton-wx4jd
    @GrahamBurton-wx4jd Před 14 dny

    hi john -thanks for explaining how this valve actually works -one question -will the valve move independenly of other contacts -ie will the valve still move from say the heating only position to the hot water only position even if the hot water thermostat is not calling for additional heat or will it stay in the hot water only position until the thermostat contact is triggered-best regatds graham

  • @awinbisa
    @awinbisa Před 14 dny

    Thanks for your amazing videos. Did you ever consider reading the shipping forecast? I love your style.

  • @tonyevic
    @tonyevic Před 15 dny

    and what is the point of terminating an earth to that fitting….? ( apart from the ‘regs’ say so!)

  • @train4905
    @train4905 Před 15 dny

    Awsome john thankyou😊😊

  • @user-ho7ez6xm3s
    @user-ho7ez6xm3s Před 15 dny

    Thank you sir.

  • @deanesau9106
    @deanesau9106 Před 16 dny

    John - Top G

  • @danstark462
    @danstark462 Před 17 dny

    John i haven't had the pleasure to see all your vids. I was wondering if you could post or repost a vid on you fixing a 12v car battery charger or a 120v electric farm fencer. Thanks. Your vids are interesting i enjoy them.

  • @lrdisco2005
    @lrdisco2005 Před 17 dny

    Excellent explanation from real world experience.

  • @altvamp
    @altvamp Před 17 dny

    It's got the right brand name, it might make you see stars! Wouldn't pass UK safety regulations.

  • @Trafficlight678
    @Trafficlight678 Před 18 dny

    In the USA we use Edison type lamp holders rather than bayonets. The Edison lamps use a screw thread system instead of push and twist

  • @Trafficlight678
    @Trafficlight678 Před 18 dny

    I am living in the USA and we measure cord thickness in the form of gauge rather than millimeter. In the USA the thickness of the flex would be 14 gauge which in the UK is 1 millimeter

  • @michaelcox2648
    @michaelcox2648 Před 18 dny

    Hi John. Can you do a video on understanding the time current characteristics in appendix 3. How do we understand the graphs?

  • @volodimirdembitskyy6516

    CHEERS !

  • @michaelcostello6991
    @michaelcostello6991 Před 18 dny

    Nice.. What about steel braided cable

    • @jwflame
      @jwflame Před 17 dny

      Could it be this useless cable: czcams.com/video/ygcj-6gcJWU/video.html

    • @michaelcostello6991
      @michaelcostello6991 Před 17 dny

      ​@@jwflame Thanks.

  • @fillyfresh
    @fillyfresh Před 18 dny

    Black and Blue. Red and Brown sauce. Good way to remember which corrosponds to which. Thanks for the videos :)

  • @FayyazMuhammad-ih8dp
    @FayyazMuhammad-ih8dp Před 19 dny

    Sir what is bond test in fluk pat tester

  • @user-fr3fo3oh7s
    @user-fr3fo3oh7s Před 19 dny

    Thank you very much sir in your tuitorial now i know to use the terminal block... ❤

  • @pjeaton58
    @pjeaton58 Před 20 dny

    Photonicinduction would love this - on a wood surface as well - only difference, Mr. Photonicinduction would get the conductor glowing bright orange, then Oh dear. " I`ve POPPED IT"

  • @pjeaton58
    @pjeaton58 Před 20 dny

    SY cable is rubbish and the braid strands are a finger piercing health & safety hazard !!

  • @Victor-by1um
    @Victor-by1um Před 20 dny

    2024, your teachings are simply sublime and still one of the best out there. Clear and concise and coherent. Thank you

  • @lgbtskylar740
    @lgbtskylar740 Před 20 dny

    Worked out its actually a weird formula, this only holds decently true with values of low r1 and r2