![KHAN GRAPHY TECHNICAL🛠️](/img/default-banner.jpg)
- 77
- 117 243
KHAN GRAPHY TECHNICAL🛠️
Registrace 13. 10. 2020
Subscribe my channel KHAN GRAPHY TECHNICAL if you need social enjoyment
mando pals ac dackt taip ac instalation paip saiz 7/8 3/4
Mando pals ac 5 tan paip saiz 7/8 3/4 hwo to mando ac 5 tan paip saiz 7/8 3/4 instation
zhlédnutí: 181
Video
fuji ac olld ❄️compressor,, 🔥, over heat
zhlédnutí 710Před měsícem
how to overhead compressor reason problem compressor Bar Bar garm Kyon Hota Hai hot compressor compressor hit hone ka problem
Gree Ac error cod E6
zhlédnutí 322Před měsícem
Hwo to Gree Ac error cod E6 Gree Ac invator error cod E6 Gree Ac me error cod E6 ka keya problam hai
L G A C compressor Piston Chowk
zhlédnutí 2,4KPřed měsícem
LG A C compressor not start how to problem compressor not start
HV AC. LG package 25 ton compressor and chakwal change
zhlédnutí 774Před měsícem
HV Ac package compressor and chakwal change new how to compressor and chakwal change
train AC error cod pu how to problem
zhlédnutí 285Před 2 měsíci
how to problem train AC error code pu train AC error cod pu
Gree Ac cassette filter up down setting
zhlédnutí 1,4KPřed 3 měsíci
Gree Ac cassette front grill uptown setting how to Gree AC cassette front grill up down setting cassette AC Gree ka front grill Kaise down up Karen
package train AC PCB and remote install
zhlédnutí 1,6KPřed 4 měsíci
package train AC PCB and remote install
L G A C error code ch 54 how to problem
zhlédnutí 257Před 4 měsíci
L G A C error code ch 54 how to problem
Fuji electric A C 2 tan casset new compressor change
zhlédnutí 10KPřed 5 měsíci
Fuji electric A C 2 tan casset new compressor change
20 tan package AC expansion oval change
zhlédnutí 415Před 7 měsíci
20 tan package AC expansion oval change
carrier AC 5 ton indoor DC PCB problem
zhlédnutí 129Před 8 měsíci
carrier AC 5 ton indoor DC PCB problem
new installation AC 1.5 tan and 2 tan
zhlédnutí 141Před 8 měsíci
new installation AC 1.5 tan and 2 tan
fauji electric 5 tan AC compressor no work
zhlédnutí 432Před 8 měsíci
fauji electric 5 tan AC compressor no work
reversing wall change Karne Ka full process
zhlédnutí 288Před 10 měsíci
reversing wall change Karne Ka full process
paikag AC 6 tan Honeywell remot practical video
zhlédnutí 490Před 11 měsíci
paikag AC 6 tan Honeywell remot practical video
gree 5 ton Inverter AC out door unit install
zhlédnutí 109Před 11 měsíci
gree 5 ton Inverter AC out door unit install
inverter LG Ac leak sealer use technical tips
zhlédnutí 84Před 11 měsíci
inverter LG Ac leak sealer use technical tips
gree AC inverter error cod P6 and P8
zhlédnutí 1,7KPřed 11 měsíci
gree AC inverter error cod P6 and P8
duck table type AC 4 ton compressor blast
zhlédnutí 1,6KPřed rokem
duck table type AC 4 ton compressor blast
Fuji electric ⚡ AC 4 ton PCB error code EEE and back referegrant
zhlédnutí 2,8KPřed rokem
Fuji electric ⚡ AC 4 ton PCB error code EEE and back referegrant
LG package AC 10 tan no cooling and leak caplri
zhlédnutí 3,4KPřed rokem
LG package AC 10 tan no cooling and leak caplri
12 tan compressor body leak electric machine welding 🥽
zhlédnutí 1,8KPřed rokem
12 tan compressor body leak electric machine welding 🥽
Ek Aisi ko service karne Mein Kitna leta hai
good service
bhai sahab aapane Har Aise Mein 09 capillary dalna Hai Kyon
tnx sr
Sar Kitna tan ka compresser
Vai jan York ka 25 ton ka pakej AC me zr 190 ka kmpershr fit Kiya lekin section line se return Nahin a raha hai 65 section pressure hi300se upr discharge pressure dikha raha hai section line se Hot 🔥 hota hi bhai ji kya reason how shkta hi 😢
Sistam ko dobarh clean kro OK dhoda gass 70 % OK 1hr ac cantenew chalu rakho
Bhai same ahi unit m mara problem kr raha h. Jab unit ko Chalate h to 10-20 minutes sahi chalta h. Uske bad liquid line 120 psi or suction line 30-35 psi ho Jata ha. Return Nahi ata compressor garam hoke band hojata h. Bhai please kuchh madat kijiye.
Electric expansion valve Ki reading check Kiya to 198ohm batata h har point m
Gas pura karo 65 se 70 take ok Agar Fir Bhi problem ho raha hai to system ko clean karo magnet vall change karke Uske Jagah per capillary lagao 09 namber ka 4 pees 30 sante metr ka lenthe caplrey ok
Bohot bohot sukria Bhai Reply krne K liye Krke dekhta hoo inshallah ho Jayega.
Very good
👍#🇵🇰
Good
Up me koun se jile ho bhai सिद्धार्थ नगर से हो का भाई बताओ यार
Bhai aap up me koun se jile se ho
Bhot khub bataya sir ❤❤❤
Good work
Good work my friend
Good bro nice teaching best of luck
❤❤❤
V
mashallah ❤❤❤
بہت ہی زیادہ آوز کر رہا ہے چند دن ہی چلیگا
2 minut ke bad Awaaz silent ho gaya tha bhai
career 6.5 ton compressor Kitna number ka keplari lagega kitna lamba Rakhna please
0.9 number ka 3 piss lamba 40 sante metres
Compressor ZR72 Ap bola 0.9 3 piss a meraoko samoj may nahe aia
please mera assa korka bataiye
Assalamu alaikum..Mera apse ye question hai ke 3/8 ke solenoid valve ki jaga 1/4 ka solenoid valve laga sakte hai kiya hot by-pass gas ke liye..please reply
Solenoid valbe 1/2 and 5/8 and 3/4 me size Aata Hai aapka Kitna tan AC hai 1.5 tan se Niche 1/2 use karo
Very good experience
Ac name what
Mine paikaz ac
Helpful always esa practical video upload kare brother ❤
Zbrdast bhai boht mehnat kiya aap
Help caihe
Keya hellp chahie
Ha bhai kaha se video bana raha hai aap
Saude
Kaam hai kaya aap ka paas
Wa Alaykumussalam
👌
Bhai AAP PCB kaise check kiye ki 3 PCB me se Kon SI PCB khrab hai kaise check kiye please help
1 pcb power ka hai aur dosra pcb control sensor ka hai yeh dono pcb par jyada lod nhe hai is leye kharab nhe hota aur 3 PCB Hai compresr ka hi use per Jyada lod padta hai isliye Jyada Vahi kharab Hota Hai
Hi
Good brother
Fuji ductable unite EE error what problome dear
Out door pcb problam
Chacha 22 ke niche nhi aa rha hai kya
👌😄😜
Bhai kanhan job kar Raha ho
Walakum asscalam bro 💚
Bro please caplari size Kon sa hai
09 caplre saiz
ithna bada trane unit ko clean karnekeliye chotavala nitrogen isthimal kar raheho..bai ...mai do mahina pahle kiya hei...capilary lamba kam karo thoda...bai
Capreei k num kaya hain or kitni lambi lagi hain
Hum nay Clean Nahi kia tha only capillary change kea thi boht acha reazalt ay tha
Bhai main b is masly men phnsa hova hon 2 dafa clean kr chuka hon lakin phr b system Chowk hy ap ny caplary nbr konsi use ki or uski lamabi ketni rakhi koi malomat dain skty hain
Caplrey no 09 OK lamba 90 snte
Ap kis city sy hain soudia men
Hamary AC may b asi problem ay thi tw hum nay new capillary lagy thi
Bhai capalary nbr btain or uski lambai ketni rakhi thi ap ny mery pas bhi yehi masla hy yar abhi clear nhi ho raha
LG inverter V ka error code ch43 ka solution Kiya. Aur is ka error code ka list batien
Super I am technition
👍
Nice video 👍
Sahi bat
Good work