Patel and Brothers
Patel and Brothers
  • 323
  • 1 677 579

Video

Compressor relay / current relay / ptc relay // potentional relay/ patel and brothers
zhlédnutí 76Před 14 dny
Compressor relay / current relay / ptc relay // potentional relay/ patel and brothers #patelandbrothers #airconditioner #refrigeration
copper to copper welding // copper to copper brajing // patel and brothers
zhlédnutí 55Před 14 dny
copper to copper welding // copper to copper brajing // patel and brothers @patelandbrothers
ice cream freezer gas top up // ice cream freezer me gas kaise top up kare // patel and brothers
zhlédnutí 43Před 14 dny
Icecream freeger gas tap up // 120 ltr freezer me gas kaise topup kare / patel and brothers compressor tripping problem czcams.com/video/loiVWdP_1S8/video.htmlsi=8RToUmvJujv5oVFT compressor on hote hi mcb trip czcams.com/video/bbZaUPr5JCw/video.htmlsi=OMN7xQtc2qv5ATtj air conditioner out door motor not workinh czcams.com/video/RPHJDg-JrJg/video.htmlsi=pSUbSdhBJAA1y1o4 @patelandbrothers @avipate...
ac me gas kitane din chalta hai / ac freeze me gas kam kaise ho jata hai / patel and brothers
zhlédnutí 71Před 21 dnem
ac me gas kitane din chalta hai / ac freeze me gas kam kaise ho jata hai / patel and brothers #patelandbrothers #aircondotioner #refrigeration
rotary compressor me accumulator ka kya kaam hota hai // working of accumulator in refeigeration
zhlédnutí 62Před 28 dny
rotary compressor me accumulator ka kya kaam hota hai // working of accumulator in refeigeration
ac ka compressor kyu fail hota hai /% compressor fail hone ke reason // patel and brothers
zhlédnutí 291Před měsícem
ac ka compressor kyu fail hota hai /% compressor fail hone ke reason // patel and brothers
r410a gas ko cylender ulta karke kyu gas charge kiya jata hai // r410 gas charging kaise kare /patel
zhlédnutí 64Před měsícem
r410a gas ko cylender ulta karke kyu gas charge kiya jata hai // r410 gas charging kaise kare /patel
Black forest cake // cake making // cace kaise bnaye / fresh cream cake
zhlédnutí 80Před měsícem
Black forest cake // cake making // cace kaise bnaye / fresh cream cake
एयर कंडीशनर में रेफ्रिजरेशन साइकिल क्या होता है/ what is refrigeration cycle // patel and brotherss
zhlédnutí 62Před 2 měsíci
एयर कंडीशनर में रेफ्रिजरेशन साइकिल क्या होता है/ what is refrigeration cycle // patel and brotherss
air conditioner is not working // ac not cooling // ac compressor tripping problem // patel brothers
zhlédnutí 87Před 2 měsíci
air conditioner is not working // ac not cooling // ac compressor tripping problem // patel brothers
which ac is best in 2024 //Kaun sa ac best hota hai // new ac 2024 // patel and brothers
zhlédnutí 54Před 5 měsíci
which ac is best in 2024 //Kaun sa ac best hota hai // new ac 2024 // patel and brothers
autometic ice cream machine // autometic icecream factory // patel and brothers
zhlédnutí 122Před 6 měsíci
autometic ice cream machine // autometic icecream factory // patel and brothers
redberry ice cream // patel and brothers // vanilla icecream
zhlédnutí 158Před 8 měsíci
redberry ice cream // patel and brothers // vanilla icecream
Icecream exhibation lucknow // icecream macine cart icecreamplant expo lucknow / patel and brothers
zhlédnutí 164Před 8 měsíci
Icecream exhibation lucknow // icecream macine cart icecreamplant expo lucknow / patel and brothers
Manual icecream cone packing machine //मैन्युअल आइसक्रीम कौन पैकिंग मशीन // patel and brothers
zhlédnutí 470Před 8 měsíci
Manual icecream cone packing machine //मैन्युअल आइसक्रीम कौन पैकिंग मशीन // patel and brothers
How to work heat and cold airconditioner || ac room ko garam kaise karta hai || patel and brothers
zhlédnutí 97Před 9 měsíci
How to work heat and cold airconditioner || ac room ko garam kaise karta hai || patel and brothers
ice cream thela gadi me gas kaise dale || fow gas charging || patel and brothers
zhlédnutí 92Před 9 měsíci
ice cream thela gadi me gas kaise dale || fow gas charging || patel and brothers
icecream आइसक्रीम फ्रीजर FOW गैस चार्जिंग की पूरी जानकारी
zhlédnutí 95Před 9 měsíci
icecream आइसक्रीम फ्रीजर FOW गैस चार्जिंग की पूरी जानकारी
कंप्रेसर कितने प्रकार से फेल होते हैं || How many ways do compressor fail || patel and brothers
zhlédnutí 102Před 9 měsíci
कंप्रेसर कितने प्रकार से फेल होते हैं || How many ways do compressor fail || patel and brothers
inverter ac ya normal ac lena chahiye || इनवर्टर एसी या नान इनवर्टर एसी लेना चाहिए || patel and brot
zhlédnutí 82Před 9 měsíci
inverter ac ya normal ac lena chahiye || इनवर्टर एसी या नान इनवर्टर एसी लेना चाहिए || patel and brot
कूल मोड और ऑटो मोड में अंतर || What is difference auto mode and cool mode ac || parel and brothers
zhlédnutí 76Před 10 měsíci
कूल मोड और ऑटो मोड में अंतर || What is difference auto mode and cool mode ac || parel and brothers
ठंडी में एयर कंडीशनर को 30°Cपर चलाएं तो रूम गर्म होगा?thandi me ac kaise kaam karta ha patel & Broth
zhlédnutí 114Před 10 měsíci
ठंडी में एयर कंडीशनर को 30°Cपर चलाएं तो रूम गर्म होगा?thandi me ac kaise kaam karta ha patel & Broth
एयर कंडीशनर रूम को कैसे ठंडा करता है!ac kaise kaam karta hai! basic theory of refrigeration patel br
zhlédnutí 79Před 10 měsíci
एयर कंडीशनर रूम को कैसे ठंडा करता है!ac kaise kaam karta hai! basic theory of refrigeration patel br
Bakery business kaise start kar/ bakery business idea/paw bread rusk tost biscuit patel and brothers
zhlédnutí 115Před 10 měsíci
Bakery business kaise start kar/ bakery business idea/paw bread rusk tost biscuit patel and brothers
pure Pital ice cream mould/पीतल आइसक्रीम मोल्ड patel and brothers
zhlédnutí 102Před 11 měsíci
pure Pital ice cream mould/पीतल आइसक्रीम मोल्ड patel and brothers
एसी बिल्कुल ठीक है लेकिन रूम ठंडा नहीं हो रहा है| air conditioner is ok but room is not getting cold
zhlédnutí 326Před 11 měsíci
एसी बिल्कुल ठीक है लेकिन रूम ठंडा नहीं हो रहा है| air conditioner is ok but room is not getting cold
Patel and brothers bathroom plumbing pipe fitting ideas
zhlédnutí 106Před rokem
Patel and brothers bathroom plumbing pipe fitting ideas
patel and brothers
zhlédnutí 627Před rokem
patel and brothers
toast and rusk packing machine //टोस्ट एंड रस्क पैकिंग मशीन//patel and brothers//red berry icecream
zhlédnutí 143Před rokem
toast and rusk packing machine //टोस्ट एंड रस्क पैकिंग मशीन//patel and brothers//red berry icecream

Komentáře

  • @SameerAhmad-jp5ov
    @SameerAhmad-jp5ov Před 4 hodinami

    Bhai Blue Star ka Ac, Hai usme R 32 &R 22 Likha hai to kya kre

  • @BkRaajOfficial94
    @BkRaajOfficial94 Před 4 dny

    Thank you bro❤❤

  • @AbhishekNimoria
    @AbhishekNimoria Před 6 dny

    Sir cool india ka chiller hai cwfs fout aa rha hai kya kre

    • @patelandbrothers
      @patelandbrothers Před 6 dny

      Compressor protection trip ka fault hai check karna hoga ek ek parametre, chalu karne per turant alarm aa rha ya chalte chalte trip ho rha

  • @kuldeepyadav8684
    @kuldeepyadav8684 Před 6 dny

    Coroma ka freez hai usame is jam rah a hai new is jam raha hai

  • @Chamiya9777
    @Chamiya9777 Před 7 dny

    Bhaiya Mera fow freez hai compressor vibration kar raha hai our gas miter 22 point dalne ke baad vibration ho raha h kiya problem hai

    • @patelandbrothers
      @patelandbrothers Před 7 dny

      Pahli baat toh 22 point gass jada hai ye btao cooling ho rahi hai, vibation ke liye neeche gromet check karo kat toh nahi gaye

  • @gdara7147
    @gdara7147 Před 10 dny

    I watched this video at 2X speed but then your voice couldn't reach normal level 🤣😜

  • @user-lz7bq5oi6p
    @user-lz7bq5oi6p Před 13 dny

    Wow

  • @user-lz7bq5oi6p
    @user-lz7bq5oi6p Před 13 dny

    Good

  • @UrwaUmer-x3j
    @UrwaUmer-x3j Před 13 dny

    Bahi mere inverter Haier ke AC pr 82 number a raha ha us ka koi solution btaen

    • @patelandbrothers
      @patelandbrothers Před 13 dny

      Kis company ka ac hai

    • @UrwaUmer-x3j
      @UrwaUmer-x3j Před 12 dny

      @@patelandbrothers gree ka ha dc inverter leken mujhy pta chl gya tha wo Celsius se faran height pr chla gya tha to mne - ka button or mode ke button ko aik Sath touch Kiya to wo theak ho gya

    • @patelandbrothers
      @patelandbrothers Před 11 dny

      @@UrwaUmer-x3j axa 82°F bta rha tha , ok bhai

  • @smartguy3286
    @smartguy3286 Před 13 dny

    Sir 2 question hay normal split aur inverter ka compressor same hota hay 410 ka ya alag? Dosra non inverter split mai 410 ya R32 ka compressor laga kar R22 gas dalay to koi nuksan to ni hoga?

    • @patelandbrothers
      @patelandbrothers Před 13 dny

      Inverter compressor alag non inverter compressor alag hota hai dono ki tchnology alag alag hoti hai ap samjane ke liye link de rahe usme jake video dekhiye czcams.com/video/LIcvENp1rxQ/video.htmlsi=NKSq_4xYvDQngUrO

  • @smartguy3286
    @smartguy3286 Před 13 dny

    R410 compressor mai R22 gas dal saktay hay non inverter Ac mai?

    • @patelandbrothers
      @patelandbrothers Před 13 dny

      R410a compressor me 22 no kyu dalna chahte ho

    • @smartguy3286
      @smartguy3286 Před 13 dny

      @@patelandbrothers sir yeh link daikha yeh admi normal split Mai R410 compressor Laga kar R22 gas dal kar Kam Ampere per Chala Raha hay czcams.com/video/1MgMkgKoc6A/video.htmlsi=rAU0qQSJAIfYeWh8

    • @patelandbrothers
      @patelandbrothers Před 12 dny

      @@smartguy3286 ha normsl ac me R410a ka compressor lga sakte hain aur R410a compressor me R22 gas bhi chal jayegi ampare bhi kam ho jayega, jitane bhi high pressure gas ke compressor hote hain wo kam ampare per hi chalte hain, ampare toh kam ho jayega lekin r410a gas ki efficiency r22 se jada hai, jab compressor r410a ka lgaya ja sakta hai to gas r22 kyu dale, r410 hi dale

    • @smartguy3286
      @smartguy3286 Před 12 dny

      @@patelandbrothers sir ziyada Kam ampere 410 normal split Mai R22 gas se hongay ya r22 gas se? Electricity saving point of view se

    • @patelandbrothers
      @patelandbrothers Před 12 dny

      @@smartguy3286 R410a hi best hai kam ampare ke liye

  • @SatishKumar-pd6hh
    @SatishKumar-pd6hh Před 22 dny

    Lekin ke baad aapne kuch aage nahi bataya.. pura matter clear kariye please.

  • @farhadalikhan9128
    @farhadalikhan9128 Před 22 dny

    Saaf kaho Ac lgwana hi nhi chyeee😂😂😂😂😂😂😂😂😂😂😂😂

  • @viknitu1
    @viknitu1 Před měsícem

    Mera indoor ac 7 minutes chalta hai or 3 minutes band rahta hai please bataye kya issue ho sakta hai ?

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Jab indoor unit band hota hai toh outdoor chla karta hai ya wo bhi band ho jata hai

    • @viknitu1
      @viknitu1 Před měsícem

      @@patelandbrothers sir indoor to on rahta hai bas outdoor ki light band ho jati hai and outdoor bhi lg ka 1.5ton non inverter AC hai

    • @patelandbrothers
      @patelandbrothers Před měsícem

      @@viknitu1 app ye btao indoor band ho rha hai ya outdoor poori problem clear btao tab toh mai solutions btaye

    • @viknitu1
      @viknitu1 Před měsícem

      @patelandbrothers sir indoor on rahta hai uski lights bhi on rahti hai but after 7 minutes outdoor cut mar jata hai and 3 minutes ke baad on hota hai

  • @subhamgaur9584
    @subhamgaur9584 Před měsícem

    Lekin

  • @navinpatel3052
    @navinpatel3052 Před měsícem

    Good information sir.

  • @singhrajputas
    @singhrajputas Před měsícem

    Sir g motar ke aage laga huaa rabar ka kya nam hai or kha se milega

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Motor gromet kisi ac repairing wale se purana le le ya new lena hai toh jis company ka ac hai usake service centre se milega

  • @lstlst57
    @lstlst57 Před měsícem

    Starting capister pahale 40-60 mfd ka use 80- 100 mfd laga sakte ha ka

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Waise lga toh sakte lekin koshish kare 40-60 ka hi lagane ki

  • @mohithighcortadvocate7101

    Apki com kha h

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Bhaiya ji mai lucknow se hun meri koi company nahi hai ager aap kuchh lena chahte hain toh hum lucknow ki 2-3 company ke no aapko de sakta hun

    • @mohithighcortadvocate7101
      @mohithighcortadvocate7101 Před měsícem

      @@patelandbrothers ji bhiyya glycol freezer chahiye number dijiye

    • @patelandbrothers
      @patelandbrothers Před měsícem

      @@mohithighcortadvocate7101 sunrise 9569785515 Rahul cool max 9044865769 Vijay cool plus 9936654496 Western freezer 8318501164

  • @mohithighcortadvocate7101

    Sir freez cahiye number dijiye

  • @mohithighcortadvocate7101

    Sir apka number

  • @rameshshinde198
    @rameshshinde198 Před měsícem

    Recipe video banao

  • @pubg-wo6qz
    @pubg-wo6qz Před měsícem

    Ser window ac 5 mint baad khed khed ker ke band ho jaata hai ,jab puri body hilne leg ke band ho jaata hai

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Sayad voltage problem hai

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Jab ac chalta hai tab voltage check karwaiye, votage sahi ho toh capacitor change karke dekh lijiye , 45 mfd ka new capacitor lga dijiye

  • @jishanjishankhan
    @jishanjishankhan Před měsícem

    6 mould icecream candy machine chahiye

  • @OPGAMER-hc8hi
    @OPGAMER-hc8hi Před měsícem

    Window ac ka compressor 5 minutes chalta hai fir band ho jata h room hisab temperature set nhi Hota condenser bhi badly liya bas kabi chaeta kabi band ho jata h kya kre

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Voltage ki kya condition hai ac chalane ke baad voltage check kariye kitane volt rahta hai

  • @sahilchamp1012
    @sahilchamp1012 Před měsícem

    @jaiprakashyadav9902 sir blustar 1.5 ton ka split ac h 4 mint chalta h aur 3 mint off rhta h sir kya reason ho sakta h plz rply

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Poora off ho jata hai ya sirf outdoor

    • @sahilchamp1012
      @sahilchamp1012 Před měsícem

      @@patelandbrothers sir sirf out door har koi alag alag salutations bata rha h aap bataiye kya problem ho sakti h sir 😞

    • @patelandbrothers
      @patelandbrothers Před měsícem

      @@sahilchamp1012 indoor ki cooling coil me ek senssor lga hoga usko coil se nikalker matlab bina coil me tauch kare tab chalaiye aur btaiye kitani der chalta hai, ek senssor cooling coil ke bilkul front me rahta hai usako nahi doosra jo pcb lagi hoti hai usake pass uper coil ke ander dla hoga senssor bhi copper ka hi hota hai usako

    • @sahilchamp1012
      @sahilchamp1012 Před měsícem

      @@patelandbrothers ok sir shukriya rply dene k liye kafi time se main pareshan hu is problem se ....

    • @sahilchamp1012
      @sahilchamp1012 Před měsícem

      @@patelandbrothers sir coil sensor hata k check kr liya abhi bhi wahi problem face aa rhi h but ab compressor 3 mint se badh kr 6 mint chal rha, 3 mint band rhta h sir pcb check krare kya sensor v bad gai h......ya relay kharab ho gai h 3 mint me suply cut kr rahi...... Ya kahiye to 1 baar capister change kr k dekhe aap suggest kriye kiya kre .....

  • @ehsanali8593
    @ehsanali8593 Před měsícem

    Air cooled chiiler me kitne indoor connect ki ja sakty h reply pls

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Ye toh chillar ki capacity per depend karta hai

    • @ehsanali8593
      @ehsanali8593 Před měsícem

      250 tr ka h to kitna indoor

    • @ehsanali8593
      @ehsanali8593 Před měsícem

      Or ek question h Air-cooled chiiler me fcu ahu ductable laga sakte h or cassette ko air cooler me connect hote h ya nhi

  • @divyanshchandak476
    @divyanshchandak476 Před měsícem

    I purchased new Split Inverter AC 1 Ton of Voltas and from the time is has been installed I am facing Compressor tripping problem in 3-4 minutes please advise

    • @patelandbrothers
      @patelandbrothers Před měsícem

      What is electric voltage condition

    • @divyanshchandak476
      @divyanshchandak476 Před měsícem

      @@patelandbrothers Sir Voltage is alright because 2 same model of AC has been installed in two different rooms . One is working fine but there is problem in other . After engineers visit by voltas service team .. they are telling that they have mailed for replacement but already 10 days have passed and there is no response. Please suggest what should I Do

  • @sksargam324
    @sksargam324 Před měsícem

    nice one but all HVAC ke new project ke bare me bataye stalatoin ke liye

  • @avipatelunnaowala5983
    @avipatelunnaowala5983 Před měsícem

    Good

  • @cubicworld8767
    @cubicworld8767 Před měsícem

    मेरा एसी दिन में 10 से 5तक चलाने पर ट्रिप कर जाता है लेकिन उसके बाद सही चलता है क्या प्रॉब्लम हो सकती है।

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Oआपका आउटडोर धूप में है क्या कभी-कभी बहुत गर्मी होने के कारण कोई फाल्ट नहीं होता तब भी कंप्रेसर ट्रिप कर जाता है

  • @dushantinsaan8435
    @dushantinsaan8435 Před měsícem

    Lloyd window AC purchased 2 yaers ago.kisi bhi temp pe set karne se 5-7mim chalke compressor band ho jata h bs fan chalta h.plz guide me

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Sabse pahle ye find out karna padega ki compressor senssor se band ho rha ya high ampare hoke tab hum kuchh bta payenge

  • @angrishkumar
    @angrishkumar Před měsícem

    Sir ac mai fanmotor bhi hota us wire ko kaha lagayege plz Reply

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Kaun sa ac hai btaiye fir hum btaye ye toh maine sirf compressor ki wiring btaya hai, waise fan motor ko relay ka jaha nutal lga rahe ho ek wire waha dusara jaha phase wala lga rahe ho waha

  • @RahulSharma-qj5wq
    @RahulSharma-qj5wq Před měsícem

    Hello, LG non inverter split 1.5 AC, compressor trip problem, 5 min chalta hain uske baad band ho jata hain, no cooling only fan running, service karwa li, capacitor change karwa liya, kya problem ho sakti hain, pls guide, outdoor unit chanv main hain

    • @hajiamirsajjad1978
      @hajiamirsajjad1978 Před měsícem

      De.

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Jab 5 minute chalta hai toh cooling hoti hai aur ampare metre lga ke check kariye jab band hone wala hota hai toh us time ampare kitna hota hao

  • @PrafuljrathodRathod-gz6si

    Kya voltas me r 410 gas he usme r22 gas dal sakte he voh Volta inverter ac he

  • @shyambiryadav7305
    @shyambiryadav7305 Před měsícem

    L3 display ho raha hai

  • @TarunMotoAdventur
    @TarunMotoAdventur Před měsícem

    Thank you

  • @dhirajjha2166
    @dhirajjha2166 Před měsícem

    Mera outdoor fan 10 min. pr band ho jata hai ....kya kare

    • @patelandbrothers
      @patelandbrothers Před měsícem

      Kaun sa ac hai inverter ya normal kewal fan band hota hai ya compressor bhi

  • @vidyabhushansrivastava7572

    Nice

  • @v.noffical2049
    @v.noffical2049 Před 2 měsíci

    Discharge pressure ka matlab...❔

    • @patelandbrothers
      @patelandbrothers Před 2 měsíci

      Discharge pressure ka matlab head pressure matlab jo pressure compressor se niklta hai use kahte hain

  • @badboyd2561
    @badboyd2561 Před 2 měsíci

    Sir lloyd outer pcb me ibm kharab hai kaise aur kanha banega

  • @Dharmu80.Dharmendrasardar
    @Dharmu80.Dharmendrasardar Před 2 měsíci

    1.5ton ka window ac kaa.compressor.koi freedz kaa compressor ke saath exchange karsakte hai ? Taaki noise.aur electricity kam ho jaye.

    • @patelandbrothers
      @patelandbrothers Před 2 měsíci

      Ji nahi freeze ka compressor bahut kam watt ka hota hai 1.5 ton ac me kaam hi nahi karega

  • @nitengurangmaakali144
    @nitengurangmaakali144 Před 2 měsíci

    Hitachi bad split

  • @SajjadRajput272
    @SajjadRajput272 Před 2 měsíci

    Jnb AC agr 4ton ka ho to b 410 gas ka pressure otna he hona chay Running m120 sy 130 ya off m 250

  • @hasmukhbutani1131
    @hasmukhbutani1131 Před 2 měsíci

    Patel sir ji bahut badhiya thanks 🙏

  • @mdzeeshan605
    @mdzeeshan605 Před 2 měsíci

    Agr 22 gas me hi thoda sa 32 mix ho gya h to usko firse wekum karke usme 22 gas dal sake h ya nahi

    • @patelandbrothers
      @patelandbrothers Před 2 měsíci

      Haa poora gas nikal dijiye fir vaccume karke 22 no dal dijiye

  • @FARAHTAli777
    @FARAHTAli777 Před 2 měsíci

    New compressor daikin non inverter ac 1.5 ton me kuan sa dlbaye

  • @namanable
    @namanable Před 2 měsíci

    SIR AC AUTO CUT NI HO RHA...HIGH (30) TEMP PE CHALANE K BAAD BHI CUT NI HO RAHA...

    • @patelandbrothers
      @patelandbrothers Před 2 měsíci

      Cooling coil ke uper sensser lga hoga usako clean karke wapas coil ke uper lga dijiye

  • @abhishekjain9503
    @abhishekjain9503 Před 2 měsíci

    Best explained

  • @anishraj.4236
    @anishraj.4236 Před 2 měsíci

    Iska diagram ka photo deception me daal dijiye na