Changing a condenser fan motor with my daughter
zhlédnutí 53Před 9 měsíci
Changing a condenser fan motor with my daughter
Changing a condenser fan motor with my daughter. Part 2
zhlédnutí 28Před 9 měsíci
Changing a condenser fan motor with my daughter. Part 2
Winning Slots on the Carnival Mardis Gras
zhlédnutí 268Před rokem
Winning Slots on the Carnival Mardis Gras
Playing and Winning the Slots on Carnival Mardis Gras
zhlédnutí 238Před rokem
Playing and Winning the Slots on Carnival Mardis Gras
Coil cleaning, Refrigeration, condenser
zhlédnutí 45Před 2 lety
Coil cleaning, Refrigeration, condenser
Heatcraft quick response board defrost issues
zhlédnutí 380Před 2 lety
Heatcraft quick response board defrost issues
Harbor Breeze 70" Hydra Fan
zhlédnutí 6KPřed 2 lety
Harbor Breeze 70" Hydra Fan
Automation Direct C-more plc-498 error code. Allen Bradley Studio 5000
zhlédnutí 1,5KPřed 3 lety
Automation Direct C-more plc-498 error code. Allen Bradley Studio 5000
Automation direct C-more PLC-026 error code. Allen Bradley Studio 5000
zhlédnutí 774Před 3 lety
Automation direct C-more PLC-026 error code. Allen Bradley Studio 5000
Fanuv LR mate Class Presentation
zhlédnutí 24Před 3 lety
Fanuv LR mate Class Presentation
C-more Studio 5000 interface
zhlédnutí 59Před 3 lety
C-more Studio 5000 interface
Fanuc LR Mate Cylinder Assembly
zhlédnutí 85Před 3 lety
Fanuc LR Mate Cylinder Assembly
Interfacing Allen Bradley 525 with studio 5000
zhlédnutí 82Před 3 lety
Interfacing Allen Bradley 525 with studio 5000
Fanuc LR mate A_CIR1 Handling pro
zhlédnutí 84Před 3 lety
Fanuc LR mate A_CIR1 Handling pro
Allen Bradley PowerFlex 525 interfacing with Studio 5000
zhlédnutí 522Před 3 lety
Allen Bradley PowerFlex 525 interfacing with Studio 5000
Tia Portal Siemens Simatic S7-300 TON, XIC, XIO, Timer Timing, Timer Enable, Timer Done.
zhlédnutí 761Před 3 lety
Tia Portal Siemens Simatic S7-300 TON, XIC, XIO, Timer Timing, Timer Enable, Timer Done.
Automation Studio Jog switch
zhlédnutí 325Před 3 lety
Automation Studio Jog switch
Understanding the Logic of XIC and XIO instructions.
zhlédnutí 886Před 3 lety
Understanding the Logic of XIC and XIO instructions.
Cape Cod Kitchen Remodel Update. Cabinets, counters, granite, and more
zhlédnutí 339Před 3 lety
Cape Cod Kitchen Remodel Update. Cabinets, counters, granite, and more
Fanuc LR-Mate 200id Cylinder Assembly First part!
zhlédnutí 106Před 3 lety
Fanuc LR-Mate 200id Cylinder Assembly First part!
Studio 5000 2nd and 3rd Project
zhlédnutí 36Před 3 lety
Studio 5000 2nd and 3rd Project
How to save in Netlabs
zhlédnutí 23Před 3 lety
How to save in Netlabs
How to screenshot using your computer
zhlédnutí 13Před 3 lety
How to screenshot using your computer
Studio 5000 First Project
zhlédnutí 72Před 3 lety
Studio 5000 First Project
Bobcat Procat RT zeroturn, learning to drive
zhlédnutí 251Před 3 lety
Bobcat Procat RT zeroturn, learning to drive
Fanuc Tool Frame Point Method Handling Pro LR Mate 200id
zhlédnutí 913Před 3 lety
Fanuc Tool Frame Point Method Handling Pro LR Mate 200id
Setting up the LR Mate 200 ID in Handling Pro Roboguide
zhlédnutí 179Před 3 lety
Setting up the LR Mate 200 ID in Handling Pro Roboguide

Komentáře

  • @allenquintana2868
    @allenquintana2868 Před 18 hodinami

    Nice 👍

  • @DANIAC262
    @DANIAC262 Před 5 dny

    White blades look good😊

  • @michaelerickson1518

    We fix sh t with tape

  • @skidfle
    @skidfle Před 9 dny

    I’ve just finished curing one for 4H

  • @RealityCheck787
    @RealityCheck787 Před 14 dny

    How did you install the LED light kit?

  • @eco-solutionsllc4412
    @eco-solutionsllc4412 Před 24 dny

    Lol , Master Bruce

  • @scoobtoober2975
    @scoobtoober2975 Před měsícem

    would you throw the canvas away? and just sheet it

    • @daviscfad
      @daviscfad Před měsícem

      the canvas helps with noise

  • @user-ff7iq5ss4w
    @user-ff7iq5ss4w Před měsícem

    How do you compact?

    • @daviscfad
      @daviscfad Před měsícem

      I just back fill then run over it qith the trencher and backfill some nore

    • @abijahgribble
      @abijahgribble Před 22 dny

      The ones that care about the yard greatly will pack with a sledgehammer then rake in the backfill, the results are amazing, but it is time consuming and eats your lunch

    • @daviscfad
      @daviscfad Před 21 dnem

      @abijahgribble2249 yea most people don't wanna pay that extra time

    • @abijahgribble
      @abijahgribble Před 21 dnem

      @daviscfad most definitely, I'm a foreman contracted through a prestigious gas company and they respect the final product a whole lot more, especially in established residences. If that pack ain't right boy them customers come calling as soon as a heavy rain hits and she sinks even a half inch 🤣

    • @daviscfad
      @daviscfad Před 21 dnem

      @abijahgribble2249 oh yea it dont take much

  • @pcgtrader
    @pcgtrader Před měsícem

    hey David, what outlet pressure should i be aiming for on a gas valve converted for propane?

    • @daviscfad
      @daviscfad Před měsícem

      always go by the manufacturer specs usually listed on the equipment

    • @pcgtrader
      @pcgtrader Před měsícem

      @@daviscfad thats the problem im having, nowhere on the nameplate for the furnace nor the manual for this gas valve does it show pressures for propane converted only for ng. the valve is field converted and i know how to check and adjust the pressure just stumped on what exactly to put it at, right now it's floating right around 7inwc

    • @daviscfad
      @daviscfad Před měsícem

      usually supply wc is 11 to 14on the inlet side of the regulator

    • @pcgtrader
      @pcgtrader Před měsícem

      @@daviscfad yup ive got 14 on inlet side. im thinking the 7 on the outlet side here is too low as the exhaust pipe is all sooted up. just for context im trying to resolve a poorly burning unit, big blast of flame on startup and sootlined exhaust pipe has me thinking too low pressure. i may just order a new conversion kit and redo it hoping that desired outlet pressure will be in those instructions w the kit. thanks for your fast replies

    • @daviscfad
      @daviscfad Před měsícem

      @@pcgtrader have you checked the burners to make sure they aren't rusted up

  • @mariog6649
    @mariog6649 Před měsícem

    Your video just saved me a lot of time, thanks !!

  • @anthony3953
    @anthony3953 Před měsícem

    How fast? Looks great btw

    • @daviscfad
      @daviscfad Před měsícem

      with the appion pump like 2 mins

    • @beefing313
      @beefing313 Před měsícem

      👍🏾👍🏾👍🏾

  • @jabroski69
    @jabroski69 Před měsícem

    Mine is kicking out in the first two seconds and is drawing 35 Amps

  • @BotvacProductions469
    @BotvacProductions469 Před 2 měsíci

    swept blades!

  • @spydaaz
    @spydaaz Před 2 měsíci

    Do you ever use both tape and sealant?

  • @chinookpro
    @chinookpro Před 2 měsíci

    My error was 0x050000. Realized I had some tags in the Cmore project that were not in the PLC. Deleting them solved the error. Thank you!

  • @Honestandtruth
    @Honestandtruth Před 2 měsíci

    Thank you for this info 👍

  • @user-eu4jo6kf7o
    @user-eu4jo6kf7o Před 2 měsíci

    I,m think the abaut you ,brother

  • @user-eu4jo6kf7o
    @user-eu4jo6kf7o Před 2 měsíci

    Good job....🎉

  • @Sparky-ww5re
    @Sparky-ww5re Před 2 měsíci

    That's pretty wild. 3 years ago I went on a service call, to a 1960s diner that I and two fellow electricians were working on just a couple of days prior replacing the main panelboard. One of the janitors plugged in a floor polisher that went unusually fast and smoked up. Supply was 120/240 3 phase delta, there was also a single phase subpanel feeding the lighting, security system and some of the receptacle loads, and I was rushing because it was close to midnight when we finished and installed the stinger leg on phase B according to the 2020 NEC, without confirming from my partner who removed the old panel which phase the stinger was on, it was originally on phase C, and he didn't confirm with me where I landed it. The security system was unharmed because it had been on phase A, and the lights were F32T8 electronic ballasts that were 120~277V, so they were fine on the 208V stinger, therefore everything was normal when we left, but we definitely should have verified voltages. Oops.

  • @ConstructionVest
    @ConstructionVest Před 3 měsíci

    I use both

  • @emoneyblue
    @emoneyblue Před 3 měsíci

    Tip: You can take it a step farther a rinse the butter in cold water a few times to remove even more of the buttermilk and the butter will last even longer .

  • @emoneyblue
    @emoneyblue Před 3 měsíci

    Commercial coolers take around 25lbs when topping them off ? I have a coke cooler it holds 16.5 Oz and I topped it off to around 5lbs and it’s cooling should I have added more?

    • @daviscfad
      @daviscfad Před 3 měsíci

      You have to go by nameplate

  • @googleaccount2397
    @googleaccount2397 Před 3 měsíci

    Heh.... Jacket off

  • @fritzhoffmann9746
    @fritzhoffmann9746 Před 3 měsíci

    I call BS! No new wire or new lug. Electrical tape and wire brushed the lug.

  • @michaelk8620
    @michaelk8620 Před 3 měsíci

    Lucky no fire

  • @radiospank
    @radiospank Před 3 měsíci

    Didn’t know lose bolts cause heat like that

    • @daviscfad
      @daviscfad Před 3 měsíci

      Oh yea. It creates heat when the connection is loose

  • @robertstack2144
    @robertstack2144 Před 3 měsíci

    How much did the customer pay for that?

    • @daviscfad
      @daviscfad Před 3 měsíci

      1 million dollars 🤑

  • @justezlivn
    @justezlivn Před 3 měsíci

    Maybe investigate the reason it did that. If you just replace the wire and the lug, would it stand to reason there was a cause?

    • @daviscfad
      @daviscfad Před 3 měsíci

      The wire was replaced several months ago, and has been fine. This panel is old and will be replaced this summer. To my knowledge it's never been pmed

  • @smashingken1
    @smashingken1 Před 3 měsíci

    That's not a repair job It's a service upgrade. It's going to happen again to much load being used. Needing a 200amp

    • @daviscfad
      @daviscfad Před 3 měsíci

      It's for sure on the verge if being overloaded

  • @sonotsoo
    @sonotsoo Před 3 měsíci

    Dang it was red hot 🔥

  • @theotheralan5511
    @theotheralan5511 Před 3 měsíci

    No torque marks on those lugs, no anti seize, definitely 😁 wasn't inspected it never would have passed.

    • @daviscfad
      @daviscfad Před 3 měsíci

      This was done probably 40 to 50 years ago

  • @gilmarperez8752
    @gilmarperez8752 Před 3 měsíci

    , pull the blower out, recover the Freon and pull the coil

  • @michaelg5070
    @michaelg5070 Před 3 měsíci

    Thats likely a contributing factor to the failure. Should have been a suction core before that suction bell screen. Its not common to see those screens clogged up like that.

    • @daviscfad
      @daviscfad Před 3 měsíci

      It actually had a core drier filter installed. So I'm not sure how it got that stopped up. I know it was converted from 22 to 407c

    • @michaelg5070
      @michaelg5070 Před 3 měsíci

      @@daviscfad makes sense now. for any conversion from Mineral Oil to POE, the result will be stuff moving through the system and causing liquid driers, txv cleanouts, suction cores, liq cores to clog. The remaining Mineral in the system coagulates. Also, in any Mineral to POE conversion, it is recommended to change all BVs on the high side and TXV bodies. That is totally an unusual find. Just recently happened to a customer, nobody could figure out why the comp suction pressure wouldnt change while running.

  • @MiguelMendez-sf8bv
    @MiguelMendez-sf8bv Před 3 měsíci

    Arc flash causes getting hotter melting aluminum copper

  • @ryanyork837
    @ryanyork837 Před 3 měsíci

    If it gives you the option I would install a main breaker for overcurrent protection. That will help prevent Is that from happening

  • @paulgeorge2099
    @paulgeorge2099 Před 3 měsíci

    It doesn't really get much closer than that.

  • @paulgeorge2099
    @paulgeorge2099 Před 3 měsíci

    Burning down the house😲

    • @daviscfad
      @daviscfad Před 3 měsíci

      Isn't that tim the tool man taylors theme song

  • @P9rkour90
    @P9rkour90 Před 3 měsíci

    I wanna see you use it on the air duct connects

  • @narrowgoat-scout
    @narrowgoat-scout Před 3 měsíci

    Those damn building regulations. And god damn electrical inspections.. fxcking electrical saftey. Health and safety bollocks... is what everyone says until this happens....

  • @tingokuman
    @tingokuman Před 3 měsíci

    Who is the DODOs that say a Trane is not good. They probably don't know how to install or repair them properly. I've never seen a Trane break down including mine which has to be 35 years old. Now that I know a Mitsubishi is Trane a Heatpump will be by next upgrade.

  • @Lakeman3211
    @Lakeman3211 Před 3 měsíci

    I’ve seen a very loose spade on a meter get red hot too….the whole meter base had to be changed out….

  • @mylesm7947
    @mylesm7947 Před 3 měsíci

    Lucky it didn't destroy the buss bar.

  • @Hohmies86
    @Hohmies86 Před 4 měsíci

    I’ve seen that before, it was after hurricane Laura and the lineman swapped the neutral and one of the hots on my brother in laws house. He called me and said man my fans are all running stupid fast, my A/C is blasting air out the vents…. “TURN YOUR MAIN OFF ILL BE RIGHT THERE!” That house would’ve burned down

  • @jonathancortes4704
    @jonathancortes4704 Před 4 měsíci

    That's all set up and still get plc-26 error

    • @daviscfad
      @daviscfad Před 3 měsíci

      Unfortunately I don't work at the college anymore so I wouldn't be able to assist any further. I hope you get it figured out. It's most likely a setting wrong

  • @user-eu5vh2iz4f
    @user-eu5vh2iz4f Před 4 měsíci

    Traducir en español

  • @Tagerrun
    @Tagerrun Před 4 měsíci

    Do you have a video of how you guys replaced the wire and the lug that would be sweet to see!

    • @daviscfad
      @daviscfad Před 3 měsíci

      Unfortunately we don't. It was ran into a junction box about 15 foot away. We were able to disconnect the old one and reconnect the new one with a split bolt. Took like an hour to replace. Has been running great for 6 months but the plan is to replace it this summer

  • @ratulelectricalbd114
    @ratulelectricalbd114 Před 4 měsíci

    ❤❤❤❤

  • @user-um5xi7wc4b
    @user-um5xi7wc4b Před 4 měsíci

    Code is over rated

  • @blancaestela6714
    @blancaestela6714 Před 4 měsíci

    Where can I order a back fill blade ?

    • @daviscfad
      @daviscfad Před 4 měsíci

      I got mine with the trencher

  • @lav8378
    @lav8378 Před 4 měsíci

    When checking we can use either color of lead. Ex: I watch other video, some guys use red for common and black for Fan.

    • @daviscfad
      @daviscfad Před 4 měsíci

      Yea it doesn't matter the lead, only the setting and that you have one on common and the other ones on herm or fan